There were two analytical methods for the determination of 12 carbonyl compounds (CCs) by using liquid chromatography (LC) coupled with mass spectrometry (MS/MS) and diode array detector (UV/DAD) that were developed and applied to 52 samples that were collected in 10 workplaces. Linearity (0.996 < R2 < 0.999), intra-day repeatability (0.7 < RSD% < 10), and inter-day repeatability (5 < RSD% < 16) were acceptable for both techniques, but the highest sensibility of the MS/MS method allowed us to correctly quantify 98% of the samples (versus 32% by UV/DAD). The comparison of the concentrations that were obtained by quantifying the same sample with both techniques showed good agreement for acetaldehyde and formaldehyde (0.1 < % deviation < 30) but much higher for the less abundant congeners. In real samples, formaldehyde was the most abundant congener (concentrations between 2.7 and 77 µg m-3), followed by acetaldehyde (concentrations between 1.5 and 79 µg m-3) and butyraldehyde (concentrations between 0.4 and 13 µg m-3). In all the beauty salon samples, instead, the most abundant congener was acetaldehyde (concentrations between 19 and 79 µg m-3), probably associated with the use of beauty products. Principal components analysis (PCA) confirms the ubiquitous character of formaldehyde and highlights the influence of minority CCs on different workplaces.
Determination of carbonyl compounds in different work environments. Comparison between LC-UV/DAD and LC-MS/MS detection methods / Castellani, Federica; Antonucci, Arianna; Pindinello, Ivano; Protano, Carmela; Vitali, Matteo. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - 19:19(2022), pp. 1-20. [10.3390/ijerph191912052]
Determination of carbonyl compounds in different work environments. Comparison between LC-UV/DAD and LC-MS/MS detection methods
Castellani, FedericaPrimo
;Antonucci, AriannaSecondo
;Pindinello, Ivano;Protano, CarmelaPenultimo
;Vitali, Matteo
Ultimo
2022
Abstract
There were two analytical methods for the determination of 12 carbonyl compounds (CCs) by using liquid chromatography (LC) coupled with mass spectrometry (MS/MS) and diode array detector (UV/DAD) that were developed and applied to 52 samples that were collected in 10 workplaces. Linearity (0.996 < R2 < 0.999), intra-day repeatability (0.7 < RSD% < 10), and inter-day repeatability (5 < RSD% < 16) were acceptable for both techniques, but the highest sensibility of the MS/MS method allowed us to correctly quantify 98% of the samples (versus 32% by UV/DAD). The comparison of the concentrations that were obtained by quantifying the same sample with both techniques showed good agreement for acetaldehyde and formaldehyde (0.1 < % deviation < 30) but much higher for the less abundant congeners. In real samples, formaldehyde was the most abundant congener (concentrations between 2.7 and 77 µg m-3), followed by acetaldehyde (concentrations between 1.5 and 79 µg m-3) and butyraldehyde (concentrations between 0.4 and 13 µg m-3). In all the beauty salon samples, instead, the most abundant congener was acetaldehyde (concentrations between 19 and 79 µg m-3), probably associated with the use of beauty products. Principal components analysis (PCA) confirms the ubiquitous character of formaldehyde and highlights the influence of minority CCs on different workplaces.File | Dimensione | Formato | |
---|---|---|---|
Castellani_Determination_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.16 MB
Formato
Adobe PDF
|
1.16 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.