A novel video processing-based method for remote estimation of the respiratory rate (RR) is proposed. Relying on the fact that breathing involves quasi-periodic movements, this technique employs a generalized model of pixel-wise periodicity and applies a maximum likelihood (ML) criterion. The system first selects suitable regions of interest (ROI) mainly affected by respiratory movements. The obtained ROI are jointly analyzed for the estimation of the fundamental frequency, which is strictly related to the RR of the patient. A large motion detection algorithm is also applied, in order to exclude, from RR estimation, ROI possibly affected by unrelated large movements. The RRs estimated by the proposed system are compared with those extracted by a pneumograph and a previously proposed video processing algorithm. The results, albeit preliminary, show a good agreement with the pneumograph and a clear improvement over the previously proposed algorithm.
Respiratory rate monitoring by maximum likelihood video processing / Alinovi, D.; Ferrari, G.; Pisani, F.; Raheli, R.. - (2017), pp. 172-177. (Intervento presentato al convegno 2016 IEEE International Symposium on Signal Processing and Information Technology, ISSPIT 2016 tenutosi a Limassol, Cyprus) [10.1109/ISSPIT.2016.7886029].
Respiratory rate monitoring by maximum likelihood video processing
Pisani F.;
2017
Abstract
A novel video processing-based method for remote estimation of the respiratory rate (RR) is proposed. Relying on the fact that breathing involves quasi-periodic movements, this technique employs a generalized model of pixel-wise periodicity and applies a maximum likelihood (ML) criterion. The system first selects suitable regions of interest (ROI) mainly affected by respiratory movements. The obtained ROI are jointly analyzed for the estimation of the fundamental frequency, which is strictly related to the RR of the patient. A large motion detection algorithm is also applied, in order to exclude, from RR estimation, ROI possibly affected by unrelated large movements. The RRs estimated by the proposed system are compared with those extracted by a pneumograph and a previously proposed video processing algorithm. The results, albeit preliminary, show a good agreement with the pneumograph and a clear improvement over the previously proposed algorithm.File | Dimensione | Formato | |
---|---|---|---|
60_Respiratory rate monitoring by maximum likelihood video processing.pdf
solo gestori archivio
Note: Alinovi_Respiratory Rate Monitoring_2017
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
661.91 kB
Formato
Adobe PDF
|
661.91 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.