Background & Aims: Artificial intelligence (AI) may detect colorectal polyps that have been missed due to perceptual pitfalls. By reducing such miss rate, AI may increase the detection of colorectal neoplasia leading to a higher degree of colorectal cancer (CRC) prevention. Methods: Patients undergoing CRC screening or surveillance were enrolled in 8 centers (Italy, UK, US), and randomized (1:1) to undergo 2 same-day, back-to-back colonoscopies with or without AI (deep learning computer aided diagnosis endoscopy) in 2 different arms, namely AI followed by colonoscopy without AI or vice-versa. Adenoma miss rate (AMR) was calculated as the number of histologically verified lesions detected at second colonoscopy divided by the total number of lesions detected at first and second colonoscopy. Mean number of lesions detected in the second colonoscopy and proportion of false negative subjects (no lesion at first colonoscopy and at least 1 at second) were calculated. Odds ratios (ORs) and 95% confidence intervals (CIs) were adjusted by endoscopist, age, sex, and indication for colonoscopy. Adverse events were also measured. Results: A total of 230 subjects (116 AI first, 114 standard colonoscopy first) were included in the study analysis. AMR was 15.5% (38 of 246) and 32.4% (80 of 247) in the arm with AI and non-AI colonoscopy first, respectively (adjusted OR, 0.38; 95% CI, 0.23–0.62). In detail, AMR was lower for AI first for the ≤5 mm (15.9% vs 35.8%; OR, 0.34; 95% CI, 0.21–0.55) and nonpolypoid lesions (16.8% vs 45.8%; OR, 0.24; 95% CI, 0.13–0.43), and it was lower both in the proximal (18.3% vs 32.5%; OR, 0.46; 95% CI, 0.26–0.78) and distal colon (10.8% vs 32.1%; OR, 0.25; 95% CI, 0.11–0.57). Mean number of adenomas at second colonoscopy was lower in the AI-first group as compared with non-AI colonoscopy first (0.33 ± 0.63 vs 0.70 ± 0.97, P < .001). False negative rates were 6.8% (3 of 44 patients) and 29.6% (13 of 44) in the AI and non-AI first arms, respectively (OR, 0.17; 95% CI, 0.05–0.67). No difference in the rate of adverse events was found between the 2 groups. Conclusions: AI resulted in an approximately 2-fold reduction in miss rate of colorectal neoplasia, supporting AI-benefit in reducing perceptual errors for small and subtle lesions at standard colonoscopy. ClinicalTrials.gov, Number: NCT03954548.

Impact of Artificial Intelligence on Miss Rate of Colorectal Neoplasia / Wallace, M. B.; Sharma, P.; Bhandari, P.; East, J.; Antonelli, G.; Lorenzetti, R.; Vieth, M.; Speranza, I.; Spadaccini, M.; Desai, M.; Lukens, F. J.; Babameto, G.; Batista, D.; Singh, D.; Palmer, W.; Ramirez, F.; Palmer, R.; Lunsford, T.; Ruff, K.; Bird-Liebermann, E.; Ciofoaia, V.; Arndtz, S.; Cangemi, D.; Puddick, K.; Derfus, G.; Johal, A. S.; Barawi, M.; Longo, L.; Moro, L.; Repici, A.; Hassan, C.. - In: GASTROENTEROLOGY. - ISSN 0016-5085. - 163:1(2022), pp. 295-304. [10.1053/j.gastro.2022.03.007]

Impact of Artificial Intelligence on Miss Rate of Colorectal Neoplasia

Antonelli G.;Speranza I.;
2022

Abstract

Background & Aims: Artificial intelligence (AI) may detect colorectal polyps that have been missed due to perceptual pitfalls. By reducing such miss rate, AI may increase the detection of colorectal neoplasia leading to a higher degree of colorectal cancer (CRC) prevention. Methods: Patients undergoing CRC screening or surveillance were enrolled in 8 centers (Italy, UK, US), and randomized (1:1) to undergo 2 same-day, back-to-back colonoscopies with or without AI (deep learning computer aided diagnosis endoscopy) in 2 different arms, namely AI followed by colonoscopy without AI or vice-versa. Adenoma miss rate (AMR) was calculated as the number of histologically verified lesions detected at second colonoscopy divided by the total number of lesions detected at first and second colonoscopy. Mean number of lesions detected in the second colonoscopy and proportion of false negative subjects (no lesion at first colonoscopy and at least 1 at second) were calculated. Odds ratios (ORs) and 95% confidence intervals (CIs) were adjusted by endoscopist, age, sex, and indication for colonoscopy. Adverse events were also measured. Results: A total of 230 subjects (116 AI first, 114 standard colonoscopy first) were included in the study analysis. AMR was 15.5% (38 of 246) and 32.4% (80 of 247) in the arm with AI and non-AI colonoscopy first, respectively (adjusted OR, 0.38; 95% CI, 0.23–0.62). In detail, AMR was lower for AI first for the ≤5 mm (15.9% vs 35.8%; OR, 0.34; 95% CI, 0.21–0.55) and nonpolypoid lesions (16.8% vs 45.8%; OR, 0.24; 95% CI, 0.13–0.43), and it was lower both in the proximal (18.3% vs 32.5%; OR, 0.46; 95% CI, 0.26–0.78) and distal colon (10.8% vs 32.1%; OR, 0.25; 95% CI, 0.11–0.57). Mean number of adenomas at second colonoscopy was lower in the AI-first group as compared with non-AI colonoscopy first (0.33 ± 0.63 vs 0.70 ± 0.97, P < .001). False negative rates were 6.8% (3 of 44 patients) and 29.6% (13 of 44) in the AI and non-AI first arms, respectively (OR, 0.17; 95% CI, 0.05–0.67). No difference in the rate of adverse events was found between the 2 groups. Conclusions: AI resulted in an approximately 2-fold reduction in miss rate of colorectal neoplasia, supporting AI-benefit in reducing perceptual errors for small and subtle lesions at standard colonoscopy. ClinicalTrials.gov, Number: NCT03954548.
2022
Adenoma Miss Rate; Artificial Intelligence; Colorectal Cancer; Miss Rate; Tandem Colonoscopy
01 Pubblicazione su rivista::01a Articolo in rivista
Impact of Artificial Intelligence on Miss Rate of Colorectal Neoplasia / Wallace, M. B.; Sharma, P.; Bhandari, P.; East, J.; Antonelli, G.; Lorenzetti, R.; Vieth, M.; Speranza, I.; Spadaccini, M.; Desai, M.; Lukens, F. J.; Babameto, G.; Batista, D.; Singh, D.; Palmer, W.; Ramirez, F.; Palmer, R.; Lunsford, T.; Ruff, K.; Bird-Liebermann, E.; Ciofoaia, V.; Arndtz, S.; Cangemi, D.; Puddick, K.; Derfus, G.; Johal, A. S.; Barawi, M.; Longo, L.; Moro, L.; Repici, A.; Hassan, C.. - In: GASTROENTEROLOGY. - ISSN 0016-5085. - 163:1(2022), pp. 295-304. [10.1053/j.gastro.2022.03.007]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1669852
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 98
  • ???jsp.display-item.citation.isi??? 82
social impact