Introduction: VDD pacing system was introduced more than 30 years ago. Its use is considered by the 2021 European Society of Cardiology guidelines on cardiac pacing as a potential alternative to dual chambers system for patients with atrioventricular block and normal sinus node function. Areas covered: In this article, we performed a narrative review of current literature in order to identify the strengths and weaknesses of this pacing system. VDD system allows the maintenance of AV synchronous pacing and its hemodynamic advantages. Some disadvantages may be related to the non-negligible incidence of atrial undersensing and the possible subsequent need for upgrade to DDD system. On the other hand, shorter implantation time and lower complications rate may be advantages. Expert opinion: In the modern pacing era, VDD pacing system struggles to find its own space. However, it may still be considered as a valuable alternative to a dual-chamber pacemaker for selected patients, in specific clinical scenarios.

Single-lead VDD pacing: a literature review on short-term and long-term performance / Mei, Davide Antonio; Imberti, Jacopo Francesco; Vitolo, Marco; Bonini, Niccolò; Gerra, Luigi; Romiti, Giulio Francesco; Proietti, Marco; Lip, Gregory Y H; Boriani, Giuseppe. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - (2023). [10.1080/17434440.2023.2178901]

Single-lead VDD pacing: a literature review on short-term and long-term performance

Romiti, Giulio Francesco;
2023

Abstract

Introduction: VDD pacing system was introduced more than 30 years ago. Its use is considered by the 2021 European Society of Cardiology guidelines on cardiac pacing as a potential alternative to dual chambers system for patients with atrioventricular block and normal sinus node function. Areas covered: In this article, we performed a narrative review of current literature in order to identify the strengths and weaknesses of this pacing system. VDD system allows the maintenance of AV synchronous pacing and its hemodynamic advantages. Some disadvantages may be related to the non-negligible incidence of atrial undersensing and the possible subsequent need for upgrade to DDD system. On the other hand, shorter implantation time and lower complications rate may be advantages. Expert opinion: In the modern pacing era, VDD pacing system struggles to find its own space. However, it may still be considered as a valuable alternative to a dual-chamber pacemaker for selected patients, in specific clinical scenarios.
2023
atrial fibrillation; cardiac implantable electronic devices; cardiac resynchronization therapy; implantable cardioverter defibrillator; pacemaker; pacing
01 Pubblicazione su rivista::01a Articolo in rivista
Single-lead VDD pacing: a literature review on short-term and long-term performance / Mei, Davide Antonio; Imberti, Jacopo Francesco; Vitolo, Marco; Bonini, Niccolò; Gerra, Luigi; Romiti, Giulio Francesco; Proietti, Marco; Lip, Gregory Y H; Boriani, Giuseppe. - In: EXPERT REVIEW OF MEDICAL DEVICES. - ISSN 1743-4440. - (2023). [10.1080/17434440.2023.2178901]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1668581
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact