This study aimed to examine the clinical and esthetic outcomes of immediately provisionalized self-tapping implants placed in extraction sockets or healed edentulous ridges one year after treatment. Sixty patients in need of a single implant-supported restoration were treated with self-tapping implants (Straumann BLX) and immediate provisionalization. The implant stability quotient (ISQ) and insertion torque were recorded intraoperatively. After one year in function, the implant and prosthesis survival rate, pink esthetic score (PES), white esthetic score (WES), and marginal bone levels (MBL) were assessed. Sixty patients received 60 self-tapping implants. A total of 37 implants were placed in extraction sockets and 23 in edentulous ridges, and then all implants were immediately provisionalized. All implants achieved a high implant stability with a mean insertion torque and ISQ value of 58.1 ± 14.1 Ncm and 73.6 ± 8.1 Ncm, respectively. No significant differences were found between healed vs. post-extractive sockets (p = 0.716 and p = 0.875), or between flap vs. flapless approaches (p = 0.862 and p = 0.228) with regards to the insertion torque and ISQ value. Nonetheless, higher insertion torque values and ISQs were recorded for mandibular implants (maxilla vs. mandible, insertion torque: 55.30 + 11.25 Ncm vs. 62.41 + 17.01 Ncm, p = 0.057; ISQ: 72.05 + 8.27 vs. 76.08 + 7.37, p = 0.058). One implant did not osseointegrate, resulting in an implant survival rate of 98.3%. All implants achieved PES and WES scores higher than 12 at the 1-year follow-up. The clinical use of newly designed self-tapping implants with immediate temporization was safe and predictable. The implants achieved a good primary stability, high implant survival rate, and favorable radiographic and esthetic outcomes, regardless of the immediate or delayed placement protocols.

Immediate vs. delayed placement of immediately provisionalized self-tapping implants: a non-randomized controlled clinical trial with 1 year of follow-up / Carosi, P.; Lorenzi, C.; Di Gianfilippo, R.; Papi, P.; Laureti, A.; Wang, H. -L.; Arcuri, C.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:2(2023). [10.3390/jcm12020489]

Immediate vs. delayed placement of immediately provisionalized self-tapping implants: a non-randomized controlled clinical trial with 1 year of follow-up

Papi P.;
2023

Abstract

This study aimed to examine the clinical and esthetic outcomes of immediately provisionalized self-tapping implants placed in extraction sockets or healed edentulous ridges one year after treatment. Sixty patients in need of a single implant-supported restoration were treated with self-tapping implants (Straumann BLX) and immediate provisionalization. The implant stability quotient (ISQ) and insertion torque were recorded intraoperatively. After one year in function, the implant and prosthesis survival rate, pink esthetic score (PES), white esthetic score (WES), and marginal bone levels (MBL) were assessed. Sixty patients received 60 self-tapping implants. A total of 37 implants were placed in extraction sockets and 23 in edentulous ridges, and then all implants were immediately provisionalized. All implants achieved a high implant stability with a mean insertion torque and ISQ value of 58.1 ± 14.1 Ncm and 73.6 ± 8.1 Ncm, respectively. No significant differences were found between healed vs. post-extractive sockets (p = 0.716 and p = 0.875), or between flap vs. flapless approaches (p = 0.862 and p = 0.228) with regards to the insertion torque and ISQ value. Nonetheless, higher insertion torque values and ISQs were recorded for mandibular implants (maxilla vs. mandible, insertion torque: 55.30 + 11.25 Ncm vs. 62.41 + 17.01 Ncm, p = 0.057; ISQ: 72.05 + 8.27 vs. 76.08 + 7.37, p = 0.058). One implant did not osseointegrate, resulting in an implant survival rate of 98.3%. All implants achieved PES and WES scores higher than 12 at the 1-year follow-up. The clinical use of newly designed self-tapping implants with immediate temporization was safe and predictable. The implants achieved a good primary stability, high implant survival rate, and favorable radiographic and esthetic outcomes, regardless of the immediate or delayed placement protocols.
2023
computer-guided surgery; immediate loading; immediate placement; immediate temporization; primary stability; single implant
01 Pubblicazione su rivista::01a Articolo in rivista
Immediate vs. delayed placement of immediately provisionalized self-tapping implants: a non-randomized controlled clinical trial with 1 year of follow-up / Carosi, P.; Lorenzi, C.; Di Gianfilippo, R.; Papi, P.; Laureti, A.; Wang, H. -L.; Arcuri, C.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 12:2(2023). [10.3390/jcm12020489]
File allegati a questo prodotto
File Dimensione Formato  
Papi_Immediate_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 816.69 kB
Formato Adobe PDF
816.69 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1668072
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact