Background: The fusion of computed tomography images with non-echo planner diffusion-weighted magnetic resonance images may overcome the limitations of each individual modality. Objectives: This study aimed to assess the ability of the ’fusion’ technique to predict the location of middle ear cholesteatoma by evaluating Its impact on preoperative surgical planning and postoperative results. Methodology: Eighty-three adults with cholesteatoma underwent preoperative CT scans and non-EPI-DW-MRI with or without the ‘fusion’ technique. We evaluated cholesteatoma localization in both groups, selecting the most appropriate surgical technique, and correlating it with the intraoperative findings. Both groups were compared in terms of residual/recurrent cholesteatoma at one, six and twelve months after surgery. Results: The ‘fusion’ technique’s sensitivity, specificity, and accuracy in predicting the location of cholesteatoma were 97.5. 97.4, and 97.5%, respectively, versus 97.59, 57.69, and 73.21% of CT alone. There was a total operators agreement after the evaluation of the ’fusion’ images with the adopted surgical technique. A statistically significant decrease in residual and recurrence cholesteatoma rates was found in group A. Conclusions: The ’fusion’ technique provides the surgeon with the precise cholesteatoma location, guiding him in making the correct surgical decision, contributing to the decrease in postoperative residual and recurrence rates.

The impact of fusion imaging technique on middle ear cholesteatoma surgery. a prospective comparative study / Covelli, Edoardo; Margani, Valerio; Romano, Andrea; Volpini, Luigi; Elfarargy, Haitham H.; Bozzao and Maurizio Barbara, Alessandro. - In: ACTA OTO-LARYNGOLOGICA. - ISSN 0001-6489. - Feb 1(2023), pp. 1-8. [10.1080/00016489.2023.2172209]

The impact of fusion imaging technique on middle ear cholesteatoma surgery. a prospective comparative study

Edoardo Covelli
;
Valerio Margani;Andrea Romano;Luigi Volpini;
2023

Abstract

Background: The fusion of computed tomography images with non-echo planner diffusion-weighted magnetic resonance images may overcome the limitations of each individual modality. Objectives: This study aimed to assess the ability of the ’fusion’ technique to predict the location of middle ear cholesteatoma by evaluating Its impact on preoperative surgical planning and postoperative results. Methodology: Eighty-three adults with cholesteatoma underwent preoperative CT scans and non-EPI-DW-MRI with or without the ‘fusion’ technique. We evaluated cholesteatoma localization in both groups, selecting the most appropriate surgical technique, and correlating it with the intraoperative findings. Both groups were compared in terms of residual/recurrent cholesteatoma at one, six and twelve months after surgery. Results: The ‘fusion’ technique’s sensitivity, specificity, and accuracy in predicting the location of cholesteatoma were 97.5. 97.4, and 97.5%, respectively, versus 97.59, 57.69, and 73.21% of CT alone. There was a total operators agreement after the evaluation of the ’fusion’ images with the adopted surgical technique. A statistically significant decrease in residual and recurrence cholesteatoma rates was found in group A. Conclusions: The ’fusion’ technique provides the surgeon with the precise cholesteatoma location, guiding him in making the correct surgical decision, contributing to the decrease in postoperative residual and recurrence rates.
2023
cholesteatoma; ct scan; non-epi dw mri; fusion technique; surgical planning; recurrence
01 Pubblicazione su rivista::01a Articolo in rivista
The impact of fusion imaging technique on middle ear cholesteatoma surgery. a prospective comparative study / Covelli, Edoardo; Margani, Valerio; Romano, Andrea; Volpini, Luigi; Elfarargy, Haitham H.; Bozzao and Maurizio Barbara, Alessandro. - In: ACTA OTO-LARYNGOLOGICA. - ISSN 0001-6489. - Feb 1(2023), pp. 1-8. [10.1080/00016489.2023.2172209]
File allegati a questo prodotto
File Dimensione Formato  
Covelli_impact-of fusion-imaging-technique_2023.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.47 MB
Formato Adobe PDF
1.47 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1667763
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact