In this contribution we discuss the calibration and performance of the TOF-Wall detector of the Fragmentation-Of-Target (FOOT) experiment. A thin carbon target was irradiated with carbon ions of several energies ranging from 150 to 400 MeV/u. The charge spectra of the produced fragments were used to calibrate the energy response. The energy resolution for a single bar was about 6%. The time resolution between the two layers ranged from 42 (150 MeV/u) to 62 ps (400 MeV/u).

Calibration and performance assessment of the TOF-Wall detector of the FOOT experiment / Kraan, A.C., Battistoni, G., Belcari, N., Bisogni, M.G., Carra, P., Ciarrocchi, E., De Gregorio, A., Francesconi, M., Franciosini, G., Galli, L., Marafini, M., Marini, L., Massa, M., Moggi, A., Montefiori, M., Muraro, S., Pullia, M., Rosso, V., Sportelli, G., Traini, G., et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 1045:(2023). [10.1016/j.nima.2022.167615]

Calibration and performance assessment of the TOF-Wall detector of the FOOT experiment

Ciarrocchi E.;De Gregorio A.;Franciosini G.;Rosso V.;Sportelli G.;Traini G.;Morrocchi M.
2023

Abstract

In this contribution we discuss the calibration and performance of the TOF-Wall detector of the Fragmentation-Of-Target (FOOT) experiment. A thin carbon target was irradiated with carbon ions of several energies ranging from 150 to 400 MeV/u. The charge spectra of the produced fragments were used to calibrate the energy response. The energy resolution for a single bar was about 6%. The time resolution between the two layers ranged from 42 (150 MeV/u) to 62 ps (400 MeV/u).
2023
particle detectors; particle therapy; plastic scintillator; silicon photomultiplier
01 Pubblicazione su rivista::01a Articolo in rivista
Calibration and performance assessment of the TOF-Wall detector of the FOOT experiment / Kraan, A.C., Battistoni, G., Belcari, N., Bisogni, M.G., Carra, P., Ciarrocchi, E., De Gregorio, A., Francesconi, M., Franciosini, G., Galli, L., Marafini, M., Marini, L., Massa, M., Moggi, A., Montefiori, M., Muraro, S., Pullia, M., Rosso, V., Sportelli, G., Traini, G., et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 1045:(2023). [10.1016/j.nima.2022.167615]
File allegati a questo prodotto
File Dimensione Formato  
Kraan_Calibration-and-performance_2023.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1667285
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact