: Home monitoring supports the continuous improvement of the therapy by sharing data with healthcare professionals. It is required when life-threatening events can still occur after hospital discharge such as neonatal apnea. However, multiple sources of external noise could affect data quality and/or increase the misdetection rate. In this study, we developed a mechatronic platform for sensor characterizations and a framework to manage data in the context of neonatal apnea. The platform can simulate the movement of the abdomen in different plausible newborn positions by merging data acquired simultaneously from three-axis accelerometers and infrared sensors. We simulated nine apnea conditions combining three different linear displacements and body postures in the presence of self-generated external noise, showing how it is possible to reduce errors near to zero in phenomena detection. Finally, the development of a smart 8Ws-based software and a customizable mobile application were proposed to facilitate data management and interpretation, classifying the alerts to guarantee the correct information sharing without specialized skills.

Bionic for Training: Smart Framework Design for Multisensor Mechatronic Platform Validation / Foresti, Ruben; Statello, Rosario; Delmonte, Nicola; Lo Muzio, Francesco Paolo; Rozzi, Giacomo; Miragoli, Michele; Sarli, Leopoldo; Ferrari, Gianluigi; Macaluso, Claudio; Maggio, Marcello Giuseppe; Pisani, Francesco; Costantino, Cosimo. - In: SENSORS. - ISSN 1424-8220. - 22:1(2022). [10.3390/s22010249]

Bionic for Training: Smart Framework Design for Multisensor Mechatronic Platform Validation

Pisani, Francesco;
2022

Abstract

: Home monitoring supports the continuous improvement of the therapy by sharing data with healthcare professionals. It is required when life-threatening events can still occur after hospital discharge such as neonatal apnea. However, multiple sources of external noise could affect data quality and/or increase the misdetection rate. In this study, we developed a mechatronic platform for sensor characterizations and a framework to manage data in the context of neonatal apnea. The platform can simulate the movement of the abdomen in different plausible newborn positions by merging data acquired simultaneously from three-axis accelerometers and infrared sensors. We simulated nine apnea conditions combining three different linear displacements and body postures in the presence of self-generated external noise, showing how it is possible to reduce errors near to zero in phenomena detection. Finally, the development of a smart 8Ws-based software and a customizable mobile application were proposed to facilitate data management and interpretation, classifying the alerts to guarantee the correct information sharing without specialized skills.
2022
8Ws; bionic; neonatal apnea; three-axis accelerometer; zero-failure
01 Pubblicazione su rivista::01a Articolo in rivista
Bionic for Training: Smart Framework Design for Multisensor Mechatronic Platform Validation / Foresti, Ruben; Statello, Rosario; Delmonte, Nicola; Lo Muzio, Francesco Paolo; Rozzi, Giacomo; Miragoli, Michele; Sarli, Leopoldo; Ferrari, Gianluigi; Macaluso, Claudio; Maggio, Marcello Giuseppe; Pisani, Francesco; Costantino, Cosimo. - In: SENSORS. - ISSN 1424-8220. - 22:1(2022). [10.3390/s22010249]
File allegati a questo prodotto
File Dimensione Formato  
Bionic.pdf

accesso aperto

Note: Foresti_Bionic for Training_2022
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.44 MB
Formato Adobe PDF
2.44 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1665631
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact