Objective: Over the past 20 years valve-sparing aortic root replacement has aroused increasing interest because of a progressive attitude towards the preservation of natural tissue. Aortic reimplantation is the most used technique to spare the valve, allowing simultaneously aortic root replacement and aortic annular stabilization. The reimplantation into a graft with sinuses guarantees an optimal anatomic and functional reconstruction with established good results at 15 years. The aim of this study is to report the world longest follow-up (up to 20-years) of aortic valve reimplantation using the Valsalva graft. Methods: From February 2000 to December 2021, 265 consecutive patients with aortic root aneurysm received aortic valve reimplantation using the Valsalva graft. From 2018 leaflet plication with the routine use of caliper was performed. For each patient we performed both intraoperative and post-procedural transoesophageal echocardiography. All patients were followed with clinical assessment and echocardiography. The mean duration of follow-up was 85 ± 63 months. Results: The study cohort had a median age of 55 ± 18 and 87.2% were male. The aortic root aneurysm was associated to bicuspid aortic valve in 18.9% of patients and to Marfan syndrome in 10.6% of cases. 55.9% had an aortic regurgitation ≥ 2+. Overall survival at 15 was 87.6 ± 3.4. Freedom from cardiac death was stable at 99.6 ± 0.4 at 5, 10 and 15 years. Freedom from recurrent AR ≥ 3+ and freedom from reoperation remained stable at 10 and 15 years at 92.2 ± 2.1 and 95.9 ± 1.6, respectively. There was a minimal incidence of infective endocarditis (0.8%), thromboembolism (2.2%) and haemorrhage (2.0%). Six out of seven patients requiring reoperation had surgery in the first period of our experience (last in 2004). Early sub-optimal results had a negative effect on residual aortic regurgitation. Moreover, we hypothesized that the routine use of caliper may have contributed to a further improvement of the outcome, even if these data need to be confirmed by a longer follow-up. Conclusions: The first long term follow-up after aortic valve reimplantation using the Valsalva graft demonstrated excellent results. These long-term results gradually improved with learning curve, remaining stable during the second decade of observation. The systematic use of caliper may have contributed to a further improvement of the outcome.

Twenty-year experience of aortic valve reimplantation using the Valsalva graft / Chirichilli, Ilaria; Scaffa, Raffaele; Irace, Francesco Giosuè; Salica, Andrea; Weltert, Luca Paolo; D'Aleo, Salvatore; Chiariello, Luigi; De Paulis, Ruggero. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - (2022). [10.1093/ejcts/ezac591]

Twenty-year experience of aortic valve reimplantation using the Valsalva graft

Chirichilli, Ilaria;Irace, Francesco Giosuè;
2022

Abstract

Objective: Over the past 20 years valve-sparing aortic root replacement has aroused increasing interest because of a progressive attitude towards the preservation of natural tissue. Aortic reimplantation is the most used technique to spare the valve, allowing simultaneously aortic root replacement and aortic annular stabilization. The reimplantation into a graft with sinuses guarantees an optimal anatomic and functional reconstruction with established good results at 15 years. The aim of this study is to report the world longest follow-up (up to 20-years) of aortic valve reimplantation using the Valsalva graft. Methods: From February 2000 to December 2021, 265 consecutive patients with aortic root aneurysm received aortic valve reimplantation using the Valsalva graft. From 2018 leaflet plication with the routine use of caliper was performed. For each patient we performed both intraoperative and post-procedural transoesophageal echocardiography. All patients were followed with clinical assessment and echocardiography. The mean duration of follow-up was 85 ± 63 months. Results: The study cohort had a median age of 55 ± 18 and 87.2% were male. The aortic root aneurysm was associated to bicuspid aortic valve in 18.9% of patients and to Marfan syndrome in 10.6% of cases. 55.9% had an aortic regurgitation ≥ 2+. Overall survival at 15 was 87.6 ± 3.4. Freedom from cardiac death was stable at 99.6 ± 0.4 at 5, 10 and 15 years. Freedom from recurrent AR ≥ 3+ and freedom from reoperation remained stable at 10 and 15 years at 92.2 ± 2.1 and 95.9 ± 1.6, respectively. There was a minimal incidence of infective endocarditis (0.8%), thromboembolism (2.2%) and haemorrhage (2.0%). Six out of seven patients requiring reoperation had surgery in the first period of our experience (last in 2004). Early sub-optimal results had a negative effect on residual aortic regurgitation. Moreover, we hypothesized that the routine use of caliper may have contributed to a further improvement of the outcome, even if these data need to be confirmed by a longer follow-up. Conclusions: The first long term follow-up after aortic valve reimplantation using the Valsalva graft demonstrated excellent results. These long-term results gradually improved with learning curve, remaining stable during the second decade of observation. The systematic use of caliper may have contributed to a further improvement of the outcome.
2022
aortic regurgitation; aortic root; aortic valve; aortic valve reimplantation; aortic valve repair; leaflet plication
01 Pubblicazione su rivista::01a Articolo in rivista
Twenty-year experience of aortic valve reimplantation using the Valsalva graft / Chirichilli, Ilaria; Scaffa, Raffaele; Irace, Francesco Giosuè; Salica, Andrea; Weltert, Luca Paolo; D'Aleo, Salvatore; Chiariello, Luigi; De Paulis, Ruggero. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - (2022). [10.1093/ejcts/ezac591]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1664303
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 9
social impact