The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130Te. CUORE uses a cryogenic array of 988 TeO2 calorimeters operated at ∼10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter / Adams, D. Q.; Alduino, C.; Alfonso, K.; Avignone, F. T.; Azzolini, O.; Bari, G.; Bellini, F.; Benato, G.; Beretta, M.; Biassoni, M.; Branca, A.; Brofferio, C.; Bucci, C.; Camilleri, J.; Caminata, A.; Campani, A.; Canonica, L.; Cao, X. G.; Capelli, S.; Capelli, C.; Cappelli, L.; Cardani, L.; Carniti, P.; Casali, N.; Celi, E.; Chiesa, D.; Clemenza, M.; Copello, S.; Cremonesi, O.; Creswick, R. J.; D'Addabbo, A.; Dafinei, I.; Del Corso, F.; Dell'Oro, S.; Di Domizio, S.; Di Lorenzo, S.; Dompè, V.; Fang, D. Q.; Fantini, G.; Faverzani, M.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Fu, S. H.; Fujikawa, B. K.; Ghislandi, S.; Giachero, A.; Gianvecchio, A.; Gironi, L.; Giuliani, A.; Gorla, P.; Gotti, C.; Gutierrez, T. D.; Han, K.; Hansen, E. V.; Heeger, K. M.; Huang, R. G.; Huang, H. Z.; Johnston, J.; Keppel, G.; Kolomensky, Yu. G.; Kowalski, R.; Li, M.; Liu, R.; Ma, L.; Ma, Y. G.; Marini, L.; Maruyama, R. H.; Mayer, D.; Mei, Y.; Morganti, S.; Napolitano, T.; Nastasi, M.; Nikkel, J.; Nones, C.; Norman, E. B.; Nucciotti, A.; Nutini, I.; O'Donnell, T.; Olmi, M.; Ouellet, J. L.; Pagan, S.; Pagliarone, C. E.; Pagnanini, L.; Pallavicini, M.; Pattavina, L.; Pavan, M.; Pessina, G.; Pettinacci, V.; Pira, C.; Pirro, S.; Pozzi, S.; Previtali, E.; Puiu, A.; Quitadamo, S.; Ressa, A.; Rosenfeld, C.; Sangiorgio, S.; Schmidt, B.; Scielzo, N. D.; Sharma, V.; Singh, V.; Sisti, M.; Speller, D.; Surukuchi, P. T.; Taffarello, L.; Terranova, F.; Tomei, C.; Vetter, K. J.; Vignati, M.; Wagaarachchi, S. L.; Wang, B. S.; Welliver, B.; Wilson, J.; Wilson, K.; Winslow, L. A.; Zimmermann, S.; Zucchelli, S.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:11(2022). [10.1088/1748-0221/17/11/P11023]
An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter
Adams, D. Q.;Alduino, C.;Alfonso, K.;Avignone, F. T.;Azzolini, O.;Bari, G.;Bellini, F.;Benato, G.;Beretta, M.;Biassoni, M.;Branca, A.;Brofferio, C.;Bucci, C.;Camilleri, J.;Caminata, A.;Campani, A.;Canonica, L.;Cao, X. G.;Capelli, S.;Capelli, C.;Cappelli, L.;Cardani, L.;Carniti, P.;Casali, N.;Celi, E.;Chiesa, D.;Clemenza, M.;Copello, S.;Cremonesi, O.;Creswick, R. J.;D'Addabbo, A.;Dafinei, I.;Del Corso, F.;Dell'Oro, S.;Di Domizio, S.;Di Lorenzo, S.;Dompè, V.;Fang, D. Q.;Fantini, G.;Faverzani, M.;Ferri, E.;Ferroni, F.;Fiorini, E.;Franceschi, M. A.;Freedman, S. J.;Fu, S. H.;Fujikawa, B. K.;Ghislandi, S.;Giachero, A.;Gianvecchio, A.;Gironi, L.;Giuliani, A.;Gorla, P.;Gotti, C.;Gutierrez, T. D.;Han, K.;Hansen, E. V.;Heeger, K. M.;Huang, R. G.;Huang, H. Z.;Johnston, J.;Keppel, G.;Kolomensky, Yu. G.;Kowalski, R.;Li, M.;Liu, R.;Ma, L.;Ma, Y. G.;Marini, L.;Maruyama, R. H.;Mayer, D.;Mei, Y.;Morganti, S.;Napolitano, T.;Nastasi, M.;Nikkel, J.;Nones, C.;Norman, E. B.;Nucciotti, A.;Nutini, I.;O'Donnell, T.;Olmi, M.;Ouellet, J. L.;Pagan, S.;Pagliarone, C. E.;Pagnanini, L.;Pallavicini, M.;Pattavina, L.;Pavan, M.;Pessina, G.;Pettinacci, V.;Pira, C.;Pirro, S.;Pozzi, S.;Previtali, E.;Puiu, A.;Quitadamo, S.;Ressa, A.;Rosenfeld, C.;Sangiorgio, S.;Schmidt, B.;Scielzo, N. D.;Sharma, V.;Singh, V.;Sisti, M.;Speller, D.;Surukuchi, P. T.;Taffarello, L.;Terranova, F.;Tomei, C.;Vetter, K. J.;Vignati, M.;Wagaarachchi, S. L.;Wang, B. S.;Welliver, B.;Wilson, J.;Wilson, K.;Winslow, L. A.;Zimmermann, S.;Zucchelli, S.
2022
Abstract
The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130Te. CUORE uses a cryogenic array of 988 TeO2 calorimeters operated at ∼10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.
Cryogenic detectors; Detector modelling and simulations I (interaction of radiation with matter, interaction of photons with matter, interaction of hadrons with matter, etc); Double-beta decay detectors
01 Pubblicazione su rivista::01a Articolo in rivista
An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter / Adams, D. Q.; Alduino, C.; Alfonso, K.; Avignone, F. T.; Azzolini, O.; Bari, G.; Bellini, F.; Benato, G.; Beretta, M.; Biassoni, M.; Branca, A.; Brofferio, C.; Bucci, C.; Camilleri, J.; Caminata, A.; Campani, A.; Canonica, L.; Cao, X. G.; Capelli, S.; Capelli, C.; Cappelli, L.; Cardani, L.; Carniti, P.; Casali, N.; Celi, E.; Chiesa, D.; Clemenza, M.; Copello, S.; Cremonesi, O.; Creswick, R. J.; D'Addabbo, A.; Dafinei, I.; Del Corso, F.; Dell'Oro, S.; Di Domizio, S.; Di Lorenzo, S.; Dompè, V.; Fang, D. Q.; Fantini, G.; Faverzani, M.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Fu, S. H.; Fujikawa, B. K.; Ghislandi, S.; Giachero, A.; Gianvecchio, A.; Gironi, L.; Giuliani, A.; Gorla, P.; Gotti, C.; Gutierrez, T. D.; Han, K.; Hansen, E. V.; Heeger, K. M.; Huang, R. G.; Huang, H. Z.; Johnston, J.; Keppel, G.; Kolomensky, Yu. G.; Kowalski, R.; Li, M.; Liu, R.; Ma, L.; Ma, Y. G.; Marini, L.; Maruyama, R. H.; Mayer, D.; Mei, Y.; Morganti, S.; Napolitano, T.; Nastasi, M.; Nikkel, J.; Nones, C.; Norman, E. B.; Nucciotti, A.; Nutini, I.; O'Donnell, T.; Olmi, M.; Ouellet, J. L.; Pagan, S.; Pagliarone, C. E.; Pagnanini, L.; Pallavicini, M.; Pattavina, L.; Pavan, M.; Pessina, G.; Pettinacci, V.; Pira, C.; Pirro, S.; Pozzi, S.; Previtali, E.; Puiu, A.; Quitadamo, S.; Ressa, A.; Rosenfeld, C.; Sangiorgio, S.; Schmidt, B.; Scielzo, N. D.; Sharma, V.; Singh, V.; Sisti, M.; Speller, D.; Surukuchi, P. T.; Taffarello, L.; Terranova, F.; Tomei, C.; Vetter, K. J.; Vignati, M.; Wagaarachchi, S. L.; Wang, B. S.; Welliver, B.; Wilson, J.; Wilson, K.; Winslow, L. A.; Zimmermann, S.; Zucchelli, S.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:11(2022). [10.1088/1748-0221/17/11/P11023]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1662785
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
2
2
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.