Titanium ossicular chain replacement prosthesis is often used for rehabilitation of the columellar effect in otologic surgeries. This retrospective study aims to analyse the anatomical and functional results of surgeries in which a titanium prosthesis was used. Two hundred and eighty procedures in 256 patients operated on in a tertiary referral center were analysed. Aetiologies, preoperative audiograms, peroperative data and postoperative outcomes at 2 and 12 months postoperatively were reviewed. Chronic suppurative otitis media with or without cholesteatoma was the main aetiology (89%). There was no difference in anatomical results between partial and total ossicular replacement prosthesis, with an overall dislocation rate of 6%, and an overall extrusion rate of 3%. Regarding functional results, a postoperative air-bone gap <= 20 dB was achieved in 65% of cases, with a better result for partial compared to total ossiculoplasty (p = 0.02). A significant difference in air bone gap closure was found when comparing aetiologies, with a higher air-bone gap closure in malformation cases compared to chronic suppurative otitis media with cholesteatoma or retraction cases (p = 0.03). Ossiculoplasty using titanium prosthesis is a safe and effective procedure for rehabilitation of hearing loss, which allows reaching an air-bone gap <= 20 dB in the majority of patients.

Anatomical and functional results of ossiculoplasty using titanium prosthesis / Lahlou, G.; Sonji, G.; de Seta, D.; Mosnier, I.; Russo, F. Y.; Sterkers, O.; Bernardeschi, D.. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 1827-675X. - 38:4(2018), pp. 377-383. [10.14639/0392-100X-1700]

Anatomical and functional results of ossiculoplasty using titanium prosthesis

de Seta, D.;Russo, F. Y.;Bernardeschi, D.
Ultimo
2018

Abstract

Titanium ossicular chain replacement prosthesis is often used for rehabilitation of the columellar effect in otologic surgeries. This retrospective study aims to analyse the anatomical and functional results of surgeries in which a titanium prosthesis was used. Two hundred and eighty procedures in 256 patients operated on in a tertiary referral center were analysed. Aetiologies, preoperative audiograms, peroperative data and postoperative outcomes at 2 and 12 months postoperatively were reviewed. Chronic suppurative otitis media with or without cholesteatoma was the main aetiology (89%). There was no difference in anatomical results between partial and total ossicular replacement prosthesis, with an overall dislocation rate of 6%, and an overall extrusion rate of 3%. Regarding functional results, a postoperative air-bone gap <= 20 dB was achieved in 65% of cases, with a better result for partial compared to total ossiculoplasty (p = 0.02). A significant difference in air bone gap closure was found when comparing aetiologies, with a higher air-bone gap closure in malformation cases compared to chronic suppurative otitis media with cholesteatoma or retraction cases (p = 0.03). Ossiculoplasty using titanium prosthesis is a safe and effective procedure for rehabilitation of hearing loss, which allows reaching an air-bone gap <= 20 dB in the majority of patients.
2018
chronic suppurative otitis media with cholesteatoma; malformation; ossicular chain; ossiculoplasty; otology; adolescent; adult; aged; cholesteatoma, middle ear; hearing loss; humans; middle aged; otitis media, suppurative; prognosis; prosthesis design; recovery of function; retrospective studies; treatment outcome; tympanic membrane; young adult; ossicular prosthesis; titanium
01 Pubblicazione su rivista::01a Articolo in rivista
Anatomical and functional results of ossiculoplasty using titanium prosthesis / Lahlou, G.; Sonji, G.; de Seta, D.; Mosnier, I.; Russo, F. Y.; Sterkers, O.; Bernardeschi, D.. - In: ACTA OTORHINOLARYNGOLOGICA ITALICA. - ISSN 1827-675X. - 38:4(2018), pp. 377-383. [10.14639/0392-100X-1700]
File allegati a questo prodotto
File Dimensione Formato  
Lahlou_Anatomical and functional_2018.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 155.24 kB
Formato Adobe PDF
155.24 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1660706
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
social impact