We aimed to validate the technique of measuring the coronary flow reserve (CFR) with coronary pressure measurements against an established thermodilution technique. The CFR has traditionally required measurement of coronary blood flow velocity with the Doppler wire and, more recently, using a thermodilution technique with the coronary pressure wire. However, recent work has suggested that the CFR may be derived from pressure measurements alone (the ratio of the square root of the pressure drop across an epicardial stenosis during hyperemia to that value at rest). This depends on the assumption that friction losses across a coronary stenosis are negligible. We compared pressure-derived CFR values with those obtained by the thermodilution technique using the intracoronary pressure wire in 38 stenoses in 34 patients with significant coronary stenoses undergoing percutaneous intervention. We also compared these two techniques of measuring CFR in 25 stenoses (6 vessels) artificially created by inflating small balloons within a stented coronary artery after percutaneous intervention. There is a close linear relationship between pressure-derived and thermodilution CFR in native (r 2 = 0.52; p < 0.001) and artificial stenoses (r 2 = 0.54; p < 0.05), although the pressure-derived technique appears to systematically underestimate CFR values in both situations. This applies to native and artificial stenoses. Coronary flow reserve cannot be measured merely with pressure alone, and it cannot be safely assumed that friction losses are negligible across a native coronary stenosis. These data suggest that friction loss is an important determinant of the pressure gradient along an atherosclerotic coronary artery. © 2005 by the American College of Cardiology Foundation.

Pressure-derived measurement of coronary flow reserve / Maccarthy, P; Berger, A; Manoharan, G; Bartunek, J; Barbato, Emanuele; Wijns, W; Heyndrickx, Gr; Pijls, Nhj; De Bruyne, B.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 45:2(2005), pp. 216-220. [10.1016/j.jacc.2004.09.063]

Pressure-derived measurement of coronary flow reserve

BARBATO, EMANUELE;
2005

Abstract

We aimed to validate the technique of measuring the coronary flow reserve (CFR) with coronary pressure measurements against an established thermodilution technique. The CFR has traditionally required measurement of coronary blood flow velocity with the Doppler wire and, more recently, using a thermodilution technique with the coronary pressure wire. However, recent work has suggested that the CFR may be derived from pressure measurements alone (the ratio of the square root of the pressure drop across an epicardial stenosis during hyperemia to that value at rest). This depends on the assumption that friction losses across a coronary stenosis are negligible. We compared pressure-derived CFR values with those obtained by the thermodilution technique using the intracoronary pressure wire in 38 stenoses in 34 patients with significant coronary stenoses undergoing percutaneous intervention. We also compared these two techniques of measuring CFR in 25 stenoses (6 vessels) artificially created by inflating small balloons within a stented coronary artery after percutaneous intervention. There is a close linear relationship between pressure-derived and thermodilution CFR in native (r 2 = 0.52; p < 0.001) and artificial stenoses (r 2 = 0.54; p < 0.05), although the pressure-derived technique appears to systematically underestimate CFR values in both situations. This applies to native and artificial stenoses. Coronary flow reserve cannot be measured merely with pressure alone, and it cannot be safely assumed that friction losses are negligible across a native coronary stenosis. These data suggest that friction loss is an important determinant of the pressure gradient along an atherosclerotic coronary artery. © 2005 by the American College of Cardiology Foundation.
2005
adult; aged; article; clinical article; controlled study; coronary artery blood flow; coronary artery obstruction; coronary artery pressure; coronary stent; female; human; male; pressure measurement; priority journal; statistical significance; thermodilution; Aged; Aged; 80 and over; Algorithms; Blood Flow Velocity; Blood Pressure; Cardiac Volume; Coronary Circulation; Coronary Stenosis; Female; Heart Catheterization; Humans; Hyperemia; Male; Middle Aged; Severity of Illness Index; Thermodilution
01 Pubblicazione su rivista::01a Articolo in rivista
Pressure-derived measurement of coronary flow reserve / Maccarthy, P; Berger, A; Manoharan, G; Bartunek, J; Barbato, Emanuele; Wijns, W; Heyndrickx, Gr; Pijls, Nhj; De Bruyne, B.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 45:2(2005), pp. 216-220. [10.1016/j.jacc.2004.09.063]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1660322
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 30
social impact