Background. Dynamic changes of myocardial blood flow have been observed after reperfusion of an occluded coronary artery. MCE performed by intracoronary contrast injection can provide an estimate of microvascular flow. We hypothesized that MCE performed using intravenous infusion of a new generation contrast agent and electrocardiogram-gated harmonic imaging would be able to assess serial changes of microvascular perfusion. Objective. To study the potential of myocardial contrast echocardiography (MCE) to assess serial changes of microvascular flow during ischemia-reperfusion. Methods. Sixteen dogs underwent 90 or 180 min of left anterior descending coronary occlusion, followed by 180 min of reperfusion. Regional blood flow (RBF) was measured with fluorescent microspheres at baseline, during coronary occlusion, and at 5, 30, 90, and 180 min during reperfusion. At the same time points, MCE was performed with intravenous infusion of AF0150 (4 mg/min). Gated end-systolic images in short axis were acquired in harmonic mode and digitized on-line. Background-subtracted videointensity measured from MCE and RBF obtained from fluorescent microspheres were calculated for the risk area and for a control area, and were expressed as the ratio of the two areas. Results. After initial hyperemia, a progressive reduction in flow was observed during reperfusion. MCE correctly detected the time course of changes in flow during occlusion-reperfusion. Videointensity ratio significantly correlated with RBF data (r = 0.79; p < 0.0001). Conclusions. The progressive reduction in blood flow occurring within the postischemic microcirculation was accurately detected by MCE. This approach has potential application in the evaluation and management of postischemic reperfusion in humans.

Evaluation of Dynamic Changes in Microvascular Flow During Ischemia-Reperfusion by Myocardial Contrast Echocardiography / Galiuto, L; Demaria, An; MAY-NEWMAN, K; DEL BALZO, U; Ohmori, K; Bhargava, V; Flaim, S; Iliceto, S. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 32:4(1998), pp. 1096-1101. [10.1016/S0735-1097(98)00349-0]

Evaluation of Dynamic Changes in Microvascular Flow During Ischemia-Reperfusion by Myocardial Contrast Echocardiography

GALIUTO L;
1998

Abstract

Background. Dynamic changes of myocardial blood flow have been observed after reperfusion of an occluded coronary artery. MCE performed by intracoronary contrast injection can provide an estimate of microvascular flow. We hypothesized that MCE performed using intravenous infusion of a new generation contrast agent and electrocardiogram-gated harmonic imaging would be able to assess serial changes of microvascular perfusion. Objective. To study the potential of myocardial contrast echocardiography (MCE) to assess serial changes of microvascular flow during ischemia-reperfusion. Methods. Sixteen dogs underwent 90 or 180 min of left anterior descending coronary occlusion, followed by 180 min of reperfusion. Regional blood flow (RBF) was measured with fluorescent microspheres at baseline, during coronary occlusion, and at 5, 30, 90, and 180 min during reperfusion. At the same time points, MCE was performed with intravenous infusion of AF0150 (4 mg/min). Gated end-systolic images in short axis were acquired in harmonic mode and digitized on-line. Background-subtracted videointensity measured from MCE and RBF obtained from fluorescent microspheres were calculated for the risk area and for a control area, and were expressed as the ratio of the two areas. Results. After initial hyperemia, a progressive reduction in flow was observed during reperfusion. MCE correctly detected the time course of changes in flow during occlusion-reperfusion. Videointensity ratio significantly correlated with RBF data (r = 0.79; p < 0.0001). Conclusions. The progressive reduction in blood flow occurring within the postischemic microcirculation was accurately detected by MCE. This approach has potential application in the evaluation and management of postischemic reperfusion in humans.
1998
Microvascular Flow ; Myocardial Contrast Echocardiography
01 Pubblicazione su rivista::01a Articolo in rivista
Evaluation of Dynamic Changes in Microvascular Flow During Ischemia-Reperfusion by Myocardial Contrast Echocardiography / Galiuto, L; Demaria, An; MAY-NEWMAN, K; DEL BALZO, U; Ohmori, K; Bhargava, V; Flaim, S; Iliceto, S. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 32:4(1998), pp. 1096-1101. [10.1016/S0735-1097(98)00349-0]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1659427
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 37
social impact