BACKGROUND: [corrected] Subendocardial thickening is greater than subepicardial thickening and acute myocardial ischemia mainly impairs the former. Integrated backscatter cyclic variations (IBScv) reflect regional myocardial contractility and are blunted during myocardial ischemia. We hypothesized that stress-induced myocardial ischemia mainly affects subendocardial IBScv. METHODS AND RESULTS: Multiplane transesophageal echocardiography and simultaneous atrial pacing were performed in 12 patients without coronary artery disease (CAD) and in 25 with significant CAD. In a transgastric 2-chamber view, we calculated IBScv in subendocardium and subepicardium and a heterogeneity index, both at rest and at peak-pacing. In 27 myocardial segments of patients with normal coronary arteries, and in 16 myocardial segments supplied by coronary artery without significant stenosis in patients with CAD, there was a transmural gradient of IBScv at rest and the heterogeneity index did not change during all the protocol steps. In the 53 myocardial segments related to a significantly narrowed coronary artery, the transmural gradient of IBScv, present at rest, significantly decreased at peak-pacing because of subendocardial blunting, but promptly recovered 5 seconds after pacing interruption. Moreover, the myocardial thickening at rest and peak pacing correlated with the subendocardial IBScv behavior and not with the subepicardial one. CONCLUSIONS: IBScv are greater in the subendocardium than in the subepicardium. Atrial pacing stress test does not affect IBScv in segments supplied by nonstenotic coronary arteries, whereas it affects segments supplied by diseased coronary arteries, blunting exclusively subendocardial IBScv. Heterogeneity of IBScv intramyocardial changes caused by stress-induced ischemia must be taken into account when using IBScv for investigating myocardial ischemia

Effects of acute myocardial ischemia on intramyocardial contraction heterogeneity.A study performed with ultrasound integrated backscatter during transesophageal atrial pacing / Colonna, P; Montisci, R; Galiuto, L; Meloni, L; Iliceto, S. - In: CIRCULATION. - ISSN 0009-7322. - 100:17(1999), pp. 1770-1776.

Effects of acute myocardial ischemia on intramyocardial contraction heterogeneity.A study performed with ultrasound integrated backscatter during transesophageal atrial pacing

GALIUTO L;
1999

Abstract

BACKGROUND: [corrected] Subendocardial thickening is greater than subepicardial thickening and acute myocardial ischemia mainly impairs the former. Integrated backscatter cyclic variations (IBScv) reflect regional myocardial contractility and are blunted during myocardial ischemia. We hypothesized that stress-induced myocardial ischemia mainly affects subendocardial IBScv. METHODS AND RESULTS: Multiplane transesophageal echocardiography and simultaneous atrial pacing were performed in 12 patients without coronary artery disease (CAD) and in 25 with significant CAD. In a transgastric 2-chamber view, we calculated IBScv in subendocardium and subepicardium and a heterogeneity index, both at rest and at peak-pacing. In 27 myocardial segments of patients with normal coronary arteries, and in 16 myocardial segments supplied by coronary artery without significant stenosis in patients with CAD, there was a transmural gradient of IBScv at rest and the heterogeneity index did not change during all the protocol steps. In the 53 myocardial segments related to a significantly narrowed coronary artery, the transmural gradient of IBScv, present at rest, significantly decreased at peak-pacing because of subendocardial blunting, but promptly recovered 5 seconds after pacing interruption. Moreover, the myocardial thickening at rest and peak pacing correlated with the subendocardial IBScv behavior and not with the subepicardial one. CONCLUSIONS: IBScv are greater in the subendocardium than in the subepicardium. Atrial pacing stress test does not affect IBScv in segments supplied by nonstenotic coronary arteries, whereas it affects segments supplied by diseased coronary arteries, blunting exclusively subendocardial IBScv. Heterogeneity of IBScv intramyocardial changes caused by stress-induced ischemia must be taken into account when using IBScv for investigating myocardial ischemia
1999
ISCHEMIA-REPERFUSION INJURY
01 Pubblicazione su rivista::01a Articolo in rivista
Effects of acute myocardial ischemia on intramyocardial contraction heterogeneity.A study performed with ultrasound integrated backscatter during transesophageal atrial pacing / Colonna, P; Montisci, R; Galiuto, L; Meloni, L; Iliceto, S. - In: CIRCULATION. - ISSN 0009-7322. - 100:17(1999), pp. 1770-1776.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1659390
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 23
social impact