Tissue engineering is a multidisciplinary approach focused on the development of innovative bioartificial substitutes for damaged organs and tissues, as the skeletal muscle one. Since the loss of muscle functionality occurs in several compromised conditions, it results crucial to measure the contractility of muscle engineered tissue for studying muscle functionality in physiological and pathological conditions. Within this context, first we designed and developed an innovative device for the in-vitro measurement of engineered skeletal muscle contractility, with the use of an optical tracking algorithm. The base concept of our contractility measurement was based on the deflection of one of the two pins, designed with specific dimensions and a controlled compliance, that are commonly used to fix the engineered construct. In this work, we focused on the evaluation of the errors introduced on the measurement of contractile force by moving the positioning of the Region of Interest (ROI) from the centre one. To this, to mimic the contractile kinetics of muscle engineered tissue, known displacements of 5 µm and 10 µm at a frequency of 10 Hz were imposed through a linear actuator at the end of the elastic pin, and the images were acquired through the use of a high frequency camera mounted on a stereomicroscope for post-processing correlation. The results pointed out that the errors introduced by moving the ROI were always lower than 4% both for the one relative to the centre position and the one relative to the other six ROIs. Higher values of the relative errors occurred for the lowest nominal displacements, thus indicating that for higher displacement the errors were less influent in the positioning of the ROI along the elastic pin for the measurement of the muscle contractility.

Effects of ROI positioning on the measurement of engineered muscle tissue contractility with an optical tracking method / Forconi, F.; Apa, L.; Cosentino, M.; Musaro', Antonio; Rizzuto, E.; Del Prete, Z.. - (2022), pp. 1-5. (Intervento presentato al convegno 17th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2022 tenutosi a Messina) [10.1109/MeMeA54994.2022.9856554].

Effects of ROI positioning on the measurement of engineered muscle tissue contractility with an optical tracking method

Forconi F.;Apa L.;Cosentino M.;Musaro Antonio;Rizzuto E.;Del Prete Z.
2022

Abstract

Tissue engineering is a multidisciplinary approach focused on the development of innovative bioartificial substitutes for damaged organs and tissues, as the skeletal muscle one. Since the loss of muscle functionality occurs in several compromised conditions, it results crucial to measure the contractility of muscle engineered tissue for studying muscle functionality in physiological and pathological conditions. Within this context, first we designed and developed an innovative device for the in-vitro measurement of engineered skeletal muscle contractility, with the use of an optical tracking algorithm. The base concept of our contractility measurement was based on the deflection of one of the two pins, designed with specific dimensions and a controlled compliance, that are commonly used to fix the engineered construct. In this work, we focused on the evaluation of the errors introduced on the measurement of contractile force by moving the positioning of the Region of Interest (ROI) from the centre one. To this, to mimic the contractile kinetics of muscle engineered tissue, known displacements of 5 µm and 10 µm at a frequency of 10 Hz were imposed through a linear actuator at the end of the elastic pin, and the images were acquired through the use of a high frequency camera mounted on a stereomicroscope for post-processing correlation. The results pointed out that the errors introduced by moving the ROI were always lower than 4% both for the one relative to the centre position and the one relative to the other six ROIs. Higher values of the relative errors occurred for the lowest nominal displacements, thus indicating that for higher displacement the errors were less influent in the positioning of the ROI along the elastic pin for the measurement of the muscle contractility.
2022
17th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2022
optical tracking; ROI positioning; contractile force measurement; tissue engineering
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Effects of ROI positioning on the measurement of engineered muscle tissue contractility with an optical tracking method / Forconi, F.; Apa, L.; Cosentino, M.; Musaro', Antonio; Rizzuto, E.; Del Prete, Z.. - (2022), pp. 1-5. (Intervento presentato al convegno 17th IEEE International Symposium on Medical Measurements and Applications, MeMeA 2022 tenutosi a Messina) [10.1109/MeMeA54994.2022.9856554].
File allegati a questo prodotto
File Dimensione Formato  
Forconi _Effects-of-ROI_2022.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.18 MB
Formato Adobe PDF
4.18 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1656757
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact