Here, a novel biosensing platform for the detection of SARS-CoV-2 usable both at voltammetric and impedimetric mode is reported. The platform was constructed on a multi-walled carbon nanotubes (MWCNTs) screen-printed electrode (SPE) functionalized by methylene blue (MB), antibodies against SARS-CoV-2 spike protein (SP), a bioactive layer of chitosan (CS) and protein A (PrA). The voltammetric sensor showed superior performances both in phosphate buffer solution (PBS) and spiked-saliva samples, with LOD values of 5.0±0.1 and 30±2.1 ng/mL, compared to 20±1.8 and 50±2.5 ng/mL for the impedimetric sensor. Moreover, the voltammetric immunosensor was tested in real saliva, showing promising results.

A comparative study of voltammetric vs impedimetric immunosensor for rapid SARS‐CoV‐2 detection at the point‐of‐care / Tortolini, Cristina; Angeloni, Antonio; Antiochia, Riccarda. - In: ELECTROANALYSIS. - ISSN 1040-0397. - 34:(2023), pp. 1-11. [10.1002/elan.202200349]

A comparative study of voltammetric vs impedimetric immunosensor for rapid SARS‐CoV‐2 detection at the point‐of‐care

Tortolini, Cristina;Angeloni, Antonio;Antiochia, Riccarda
2023

Abstract

Here, a novel biosensing platform for the detection of SARS-CoV-2 usable both at voltammetric and impedimetric mode is reported. The platform was constructed on a multi-walled carbon nanotubes (MWCNTs) screen-printed electrode (SPE) functionalized by methylene blue (MB), antibodies against SARS-CoV-2 spike protein (SP), a bioactive layer of chitosan (CS) and protein A (PrA). The voltammetric sensor showed superior performances both in phosphate buffer solution (PBS) and spiked-saliva samples, with LOD values of 5.0±0.1 and 30±2.1 ng/mL, compared to 20±1.8 and 50±2.5 ng/mL for the impedimetric sensor. Moreover, the voltammetric immunosensor was tested in real saliva, showing promising results.
2023
immunosensor; sars-cov-2; voltammetricbiosensor; impedimetricbiosensor; poc diagnostics
01 Pubblicazione su rivista::01a Articolo in rivista
A comparative study of voltammetric vs impedimetric immunosensor for rapid SARS‐CoV‐2 detection at the point‐of‐care / Tortolini, Cristina; Angeloni, Antonio; Antiochia, Riccarda. - In: ELECTROANALYSIS. - ISSN 1040-0397. - 34:(2023), pp. 1-11. [10.1002/elan.202200349]
File allegati a questo prodotto
File Dimensione Formato  
Tortolini_comparative-study_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1656179
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact