A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. In this paper we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (30 J energy, 1021 W/cm2 intensity, 30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.
Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons / Salvadori, M., Andreoli, P.L., Cipriani, M., Cristofari, G., De Angelis, R., Malko, S., Volpe, L., Perez Hernandez, J.A., Apinaniz, J.I., Morace, A., Antici, P., Migliorati, M., Di Giorgio, G., Consoli, F.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:4(2022). [10.1088/1748-0221/17/04/C04005]
Time-of-flight methodologies with large-area diamond detectors for the effectively characterization of tens MeV protons
Salvadori M.;Antici P.;Migliorati M.;
2022
Abstract
A novel detector based on a polycrystalline diamond sensor is here employed in an advanced time-of-flight scheme for the characterization of energetic ions accelerated during laser-matter interactions. The optimization of the detector and of the advanced TOF methodology allow to obtain signals characterized by high signal-to-noise ratio and high dynamic range even in the most challenging experimental environments, where the interaction of high-intensity laser pulses with matter leads to effective ion acceleration, but also to the generation of strong Electromagnetic Pulses (EMPs) with intensities up to the MV/m order. These are known to be a serious threat for the fielded diagnostic systems. In this paper we report on the measurement performed with the PW-class laser system Vega 3 at CLPU (30 J energy, 1021 W/cm2 intensity, 30 fs pulses) irradiating solid targets, where both tens of MeV ions and intense EMP fields were generated. The data were analyzed to retrieve a calibrated proton spectrum and in particular we focus on the analysis of the most energetic portion (E > 5.8 MeV) of the spectrum showing a procedure to deal with the intrinsic lower sensitivity of the detector in the mentioned spectral-range.| File | Dimensione | Formato | |
|---|---|---|---|
|
Salvadori_time-of-flight_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
948.7 kB
Formato
Adobe PDF
|
948.7 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.