Background: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations.Methods: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD.Results: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values.Conclusions: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.

The "Defibrillation Testing, Why Not?" survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice / Migliore, Federico; Viani, Stefano; Ziacchi, Matteo; Ottaviano, Luca; Francia, Pietro; Bianchi, Valter; De Bonis, Silvana; De Filippo, Paolo; Tola, Gianfranco; Vicentini, Alessandro; Taravelli, Erika; Calvi, Valeria Ilia; Lovecchio, Mariolina; Valsecchi, Sergio; Botto, Giovanni Luca. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. HEART & VASCULATURE. - ISSN 2352-9067. - 38:(2022), pp. 1-6. [10.1016/j.ijcha.2022.100952]

The "Defibrillation Testing, Why Not?" survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice

Francia, Pietro;
2022

Abstract

Background: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations.Methods: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD.Results: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values.Conclusions: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT.
2022
defibrillation testing; implantable defibrillator; subcutaneous; survey
01 Pubblicazione su rivista::01a Articolo in rivista
The "Defibrillation Testing, Why Not?" survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice / Migliore, Federico; Viani, Stefano; Ziacchi, Matteo; Ottaviano, Luca; Francia, Pietro; Bianchi, Valter; De Bonis, Silvana; De Filippo, Paolo; Tola, Gianfranco; Vicentini, Alessandro; Taravelli, Erika; Calvi, Valeria Ilia; Lovecchio, Mariolina; Valsecchi, Sergio; Botto, Giovanni Luca. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. HEART & VASCULATURE. - ISSN 2352-9067. - 38:(2022), pp. 1-6. [10.1016/j.ijcha.2022.100952]
File allegati a questo prodotto
File Dimensione Formato  
Migliore_Defibrillation-Testing_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 634.41 kB
Formato Adobe PDF
634.41 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1655451
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact