Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. Objective To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. Methods Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. Results 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). Conclusions Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.

Patient acceptance of subcutaneous versus transvenous defibrillator systems: a multi-center experience / Vicentini, Alessandro; Bisignani, Giovanni; De Vivo, Stefano; Viani, Stefano; Savarese, Gianluca; Francia, Pietro; Celentano, Eduardo; Checchi, Luca; Carreras, Giovanni; Santini, Luca; Lamberti, Filippo; Ottaviano, Luca; Scalone, Antonio; Giorgi, Davide; Lovecchio, Mariolina; Valsecchi, Sergio; Rordorf, Roberto. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1540-8167. - 33:1(2022), pp. 81-89. [10.1111/jce.15297]

Patient acceptance of subcutaneous versus transvenous defibrillator systems: a multi-center experience

Francia, Pietro;
2022

Abstract

Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the transvenous ICD. No study has yet compared S-ICD and transvenous ICD by assessing patient acceptance as a patient-centered outcome. Objective To evaluate the patient acceptance of the S-ICD and to investigate its association with clinical and implantation variables. In patients with symptomatic heart failure and reduced ejection fraction (HFrEF), the acceptance of the S-ICD was compared with a control group of patients who received a transvenous ICD. Methods Patient acceptance was calculated with the Florida Patient Acceptance Survey (FPAS) which measures four factors: return to function (RTF), device-related distress (DRD), positive appraisal (PA), and body image concerns (BIC). The survey was administered 12 months after implantation. Results 176 patients underwent S-ICD implantation. The total FPAS and the single factors did not differ according to gender, body habitus, or generator positioning. Patients with HFrEF had lower FPAS and RTF. Younger patients showed better RTF (75 [56-94] vs. 56 [50-81], p = .029). Patients who experienced device complications or device therapies showed higher DRD (40 [35-60] vs. 25 [10-50], p = .019). Patients with HFrEF receiving the S-ICD had comparable FPAS, RTF, DRD, and BIC to HFrEF patients implanted with the transvenous ICD while exhibited significantly better PA (88 [75-100] vs. 81 [63-94], p = .02). Conclusions Our analysis revealed positive patient acceptance of the S-ICD, even in groups at risk of more distress such as women or patients with thinner body habitus, and regardless of the generator positioning. Among patients receiving ICDs for HFrEF, S-ICD was associated with better PA versus transvenous ICD.
2022
distressundefined; implantable defibrillatorundefined; patient acceptanceundefined; subcutaneousundefined; female; humans; stroke volume; surveys and questionnaires; treatment outcome; defibrillators, implantable; heart failure
01 Pubblicazione su rivista::01a Articolo in rivista
Patient acceptance of subcutaneous versus transvenous defibrillator systems: a multi-center experience / Vicentini, Alessandro; Bisignani, Giovanni; De Vivo, Stefano; Viani, Stefano; Savarese, Gianluca; Francia, Pietro; Celentano, Eduardo; Checchi, Luca; Carreras, Giovanni; Santini, Luca; Lamberti, Filippo; Ottaviano, Luca; Scalone, Antonio; Giorgi, Davide; Lovecchio, Mariolina; Valsecchi, Sergio; Rordorf, Roberto. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1540-8167. - 33:1(2022), pp. 81-89. [10.1111/jce.15297]
File allegati a questo prodotto
File Dimensione Formato  
Vicentini_Patient_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1655446
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact