The rehabilitation of reinforced concrete (RC) bridge columns subjected to chloride-induced corrosion is addressed in the present paper. The proposed strategy is based on the replacement of the original external layer made of normal-strength concrete (NSC) with ultra-high performance fiber reinforced concrete (UHPFRC), and it additionally involves the substitution of the existing corroded longitudinal reinforcement with new machined steel rebars. This repair technique aims at restoring strength, stiffness, and ductility of the original column in a short time without altering its cross-section dimensions. Because of the high compactness of the UHPFRC, it also serves at improving its durability. The main contribution of the present work is a numerical investigation carried out in order to identify how the design decisions about the repair strategy influence the behavior of the restored column. The parametric investigation reveals that the length of the zone in which NSC is replaced by UHPFRC as well as the machined index (i.e., ratio between turned and original rebar cross-section area) must be properly selected to make the intervention effective. Numerical results also highlight that the main design issue to deal with is the relocation of the plastic hinge from the repaired zone towards the weak unrepaired part of the column. Practical design recommendations are finally formulated.

Repair of reinforced concrete bridge columns subjected to chloride-induced corrosion with ultra-high performance fiber reinforced concrete / Pelle, A.; Briseghella, B.; Fiorentino, G.; Giaccu, G. F.; Lavorato, D.; Quaranta, G.; Rasulo, A.; Nuti, C.. - In: STRUCTURAL CONCRETE. - ISSN 1464-4177. - (2023). [10.1002/suco.202200555]

Repair of reinforced concrete bridge columns subjected to chloride-induced corrosion with ultra-high performance fiber reinforced concrete

Quaranta G.;
2023

Abstract

The rehabilitation of reinforced concrete (RC) bridge columns subjected to chloride-induced corrosion is addressed in the present paper. The proposed strategy is based on the replacement of the original external layer made of normal-strength concrete (NSC) with ultra-high performance fiber reinforced concrete (UHPFRC), and it additionally involves the substitution of the existing corroded longitudinal reinforcement with new machined steel rebars. This repair technique aims at restoring strength, stiffness, and ductility of the original column in a short time without altering its cross-section dimensions. Because of the high compactness of the UHPFRC, it also serves at improving its durability. The main contribution of the present work is a numerical investigation carried out in order to identify how the design decisions about the repair strategy influence the behavior of the restored column. The parametric investigation reveals that the length of the zone in which NSC is replaced by UHPFRC as well as the machined index (i.e., ratio between turned and original rebar cross-section area) must be properly selected to make the intervention effective. Numerical results also highlight that the main design issue to deal with is the relocation of the plastic hinge from the repaired zone towards the weak unrepaired part of the column. Practical design recommendations are finally formulated.
2023
bridge column; machined steel rebars; pitting corrosion; reinforced concrete; repair; UHPFRC
01 Pubblicazione su rivista::01a Articolo in rivista
Repair of reinforced concrete bridge columns subjected to chloride-induced corrosion with ultra-high performance fiber reinforced concrete / Pelle, A.; Briseghella, B.; Fiorentino, G.; Giaccu, G. F.; Lavorato, D.; Quaranta, G.; Rasulo, A.; Nuti, C.. - In: STRUCTURAL CONCRETE. - ISSN 1464-4177. - (2023). [10.1002/suco.202200555]
File allegati a questo prodotto
File Dimensione Formato  
Pelle_Repair_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.14 MB
Formato Adobe PDF
4.14 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1655190
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact