STUDY OBJECTIVE: To evaluate the effectiveness of the Gynecare Morcellex tissue morcellator (Ethicon, Inc., Somerville, NJ) in laparoscopic supracervical hysterectomy and myomectomy. DESIGN: Randomized controlled trial (Evidence I). SETTING: University department of obstetrics and gynecology. PATIENTS: Seventy-four patients with symptomatic uterine myomas scheduled for laparoscopic supracervical hysterectomy or myomectomy. INTERVENTIONS: Laparoscopic supracervical hysterectomy and myomectomy followed by tissue morcellation using the Gynecare Morcellex (experimental group) or the Rotocut G1 morcellator (Karl Storz GmbH & Co. KG, Tuttlingen, Germany) (control group). MEASUREMENTS AND MAIN RESULTS: Patient characteristics and surgical data were noted for both groups. No difference was detected between groups in any parameters assessed, whereas a significant difference (p <.05) in handling score was detected in the experimental group compared with the control group. CONCLUSION: The Gynecare Morcellex is an effective instrument with excellent safety and handling.
Randomized controlled study comparing the Gynecare Morcellex and Rotocut G1 tissue morcellators / Zullo, F; Falbo, A; Iuliano, A; Oppedisano, R; Sacchinelli, A; Annunziata, G; Venturella, R; Materazzo, C; Tolino, A; Palomba, S. - In: JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY. - ISSN 1553-4650. - 17:2(2010), pp. 192-199. [10.1016/j.jmig.2009.11.009]
Randomized controlled study comparing the Gynecare Morcellex and Rotocut G1 tissue morcellators.
Palomba S
2010
Abstract
STUDY OBJECTIVE: To evaluate the effectiveness of the Gynecare Morcellex tissue morcellator (Ethicon, Inc., Somerville, NJ) in laparoscopic supracervical hysterectomy and myomectomy. DESIGN: Randomized controlled trial (Evidence I). SETTING: University department of obstetrics and gynecology. PATIENTS: Seventy-four patients with symptomatic uterine myomas scheduled for laparoscopic supracervical hysterectomy or myomectomy. INTERVENTIONS: Laparoscopic supracervical hysterectomy and myomectomy followed by tissue morcellation using the Gynecare Morcellex (experimental group) or the Rotocut G1 morcellator (Karl Storz GmbH & Co. KG, Tuttlingen, Germany) (control group). MEASUREMENTS AND MAIN RESULTS: Patient characteristics and surgical data were noted for both groups. No difference was detected between groups in any parameters assessed, whereas a significant difference (p <.05) in handling score was detected in the experimental group compared with the control group. CONCLUSION: The Gynecare Morcellex is an effective instrument with excellent safety and handling.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.