A piezoelectric peptide-hpDNA based gas sensor array has been used for the detection of terpenes coming from Cannabis sativa samples. The array consisted in 11 sensors, 6 having pentapeptides and 5 having hairpin DNA as binding elements. The volatile composition of 28 Cannabis sativa samples, assessed by GC[sbnd]MS analysis, allowed their classification into 2 groups having as monoterpenes and sesquiterpenes in different amounts. The response of the gas sensor array to the same samples demonstrated that both type of sensors are sensitive to the terpenes and contribute to classification. A satisfactory classification (79 % of correctly identified samples) was found using a PLS-DA approach. Using the same dataset and a simple ANN approach the headspace analytical profile of the two different groups was predicted with an average prediction error ≤1 %.

Piezoelectric peptide-hpDNA based electronic nose for the detection of terpenes; evaluation of the aroma profile in different Cannabis sativa L. (hemp) samples / Gaggiotti, Sara; Sarapalmieri, ; Dellapelle, Flavio; Sergi, M.; Cichelli, Angelo; Mascini, Marcello; Compagnone, Dario. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - 308:(2020), pp. 1-14. [10.1016/j.snb.2020.127697]

Piezoelectric peptide-hpDNA based electronic nose for the detection of terpenes; evaluation of the aroma profile in different Cannabis sativa L. (hemp) samples

M. Sergi;Dario Compagnone
2020

Abstract

A piezoelectric peptide-hpDNA based gas sensor array has been used for the detection of terpenes coming from Cannabis sativa samples. The array consisted in 11 sensors, 6 having pentapeptides and 5 having hairpin DNA as binding elements. The volatile composition of 28 Cannabis sativa samples, assessed by GC[sbnd]MS analysis, allowed their classification into 2 groups having as monoterpenes and sesquiterpenes in different amounts. The response of the gas sensor array to the same samples demonstrated that both type of sensors are sensitive to the terpenes and contribute to classification. A satisfactory classification (79 % of correctly identified samples) was found using a PLS-DA approach. Using the same dataset and a simple ANN approach the headspace analytical profile of the two different groups was predicted with an average prediction error ≤1 %.
2020
artificial neural network; electronic nose; gas sensors; hemp; hpDNA; peptides; SPME/GC–MS; terpenes
01 Pubblicazione su rivista::01a Articolo in rivista
Piezoelectric peptide-hpDNA based electronic nose for the detection of terpenes; evaluation of the aroma profile in different Cannabis sativa L. (hemp) samples / Gaggiotti, Sara; Sarapalmieri, ; Dellapelle, Flavio; Sergi, M.; Cichelli, Angelo; Mascini, Marcello; Compagnone, Dario. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - 308:(2020), pp. 1-14. [10.1016/j.snb.2020.127697]
File allegati a questo prodotto
File Dimensione Formato  
Gaggiotti_Piezoelectric_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1653216
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact