Magnetic Resonance Imaging of the anatomy of the parotid gland. In this work are been examined the parotid gland of 30 patients (20 male, 10 female) o/ this eighteen voluntary and 12 arrived at our observation /or SNC pathology. It is been used as a superconductive magnet Philips 'gyroscan' at 1,5 T with head coi! by 35 cm and supeificial and circular coil by 20 cm. The multiplanar scan was executed with TR = 700-2000 ms and TE = 30-90 ms. The RM is been shown very accurate in the anatomic study o/ the parotid gland that appear o/ signal modest hyperintensity in the Tl -weighted images and hyperintense in the T2-weighted images /or her high contents of water that it is due to the gland part and to the stroma! fatty tissue. In 90% of the case studied we show the intraparotid way of the facial nerve in every sequence that we used, like a structure hypointense with respect to the neighboring parenchima.
Magnetic resonance imaging of the anatomy of the parotid gland / Campodonico, F.; Messineo, D.; Longo, L.. - In: VALSALVA. - ISSN 0042-2371. - 66:3(1990), pp. 134-141.
Magnetic resonance imaging of the anatomy of the parotid gland
Campodonico F.
Primo
;Messineo D.Secondo
;Longo L.Ultimo
1990
Abstract
Magnetic Resonance Imaging of the anatomy of the parotid gland. In this work are been examined the parotid gland of 30 patients (20 male, 10 female) o/ this eighteen voluntary and 12 arrived at our observation /or SNC pathology. It is been used as a superconductive magnet Philips 'gyroscan' at 1,5 T with head coi! by 35 cm and supeificial and circular coil by 20 cm. The multiplanar scan was executed with TR = 700-2000 ms and TE = 30-90 ms. The RM is been shown very accurate in the anatomic study o/ the parotid gland that appear o/ signal modest hyperintensity in the Tl -weighted images and hyperintense in the T2-weighted images /or her high contents of water that it is due to the gland part and to the stroma! fatty tissue. In 90% of the case studied we show the intraparotid way of the facial nerve in every sequence that we used, like a structure hypointense with respect to the neighboring parenchima.File | Dimensione | Formato | |
---|---|---|---|
Campodonico_Esame anatomico_1990.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.78 MB
Formato
Adobe PDF
|
2.78 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.