Aims: We report the 6-year results of our use of the Nellix endovascular aneurysm sealing system. Materials and methods: This is a retrospective review of patients we treated from 2013 to 2019. The outcomes described include technical success rate, mortality, all procedure-related complications, reinterventions, open surgical conversion and secondary sac rupture. Results and conclusions: A total of 68 patients were treated. Mortality was 2.9%. Secondary interventions were carried out for distal embolization (3), stent occlusion (1), pseudoaneurysm (1) and endoleak (5). Open surgical conversion was required in 6.4% of cases. Medium-and long-Term complications of EVAS occurred more frequently than expected. Because the durability of endovascular aneurysm sealing is questionable, strict postoperative surveillance of Nellix is crucial to identify features of failure.
Nellix endovascular aneurysm-sealing system. A single-center experience and review of current evidence / Martinelli, O.; Alunno, A.; Gattuso, R.; Di Girolamo, A.; Irace, L.. - In: FUTURE CARDIOLOGY. - ISSN 1479-6678. - 17:5(2021), pp. 875-884. [10.2217/fca-2020-0134]
Nellix endovascular aneurysm-sealing system. A single-center experience and review of current evidence
Martinelli O.;Alunno A.
;Gattuso R.;Di Girolamo A.;Irace L.
2021
Abstract
Aims: We report the 6-year results of our use of the Nellix endovascular aneurysm sealing system. Materials and methods: This is a retrospective review of patients we treated from 2013 to 2019. The outcomes described include technical success rate, mortality, all procedure-related complications, reinterventions, open surgical conversion and secondary sac rupture. Results and conclusions: A total of 68 patients were treated. Mortality was 2.9%. Secondary interventions were carried out for distal embolization (3), stent occlusion (1), pseudoaneurysm (1) and endoleak (5). Open surgical conversion was required in 6.4% of cases. Medium-and long-Term complications of EVAS occurred more frequently than expected. Because the durability of endovascular aneurysm sealing is questionable, strict postoperative surveillance of Nellix is crucial to identify features of failure.File | Dimensione | Formato | |
---|---|---|---|
Martinelli_Nellix-endovascular-aneurysm-sealing_2021.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
5.24 MB
Formato
Adobe PDF
|
5.24 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.