Abstract: Despite the application of EANM recommendations for radiolabelled white-blood-cells (WBC) scintigraphy, some cases still remain doubtful based only on visual analysis. The aim of this study was to investigate the role of semi-quantitative analysis and bone marrow scan (BMS) in solving doubtful cases. We retrospectively evaluated all [99mTc]HMPAO-WBC scintigraphies performed, in the last 7 years, for a suspected monolateral prosthetic joint infection (PJI). In doubtful cases, we used five different thresholds of increase of target-to-background (T/B) ratio, between delayed and late images, as criteria of positivity (5%, 10%, 15%, 20% and 30%). BMS were also analysed and sensitivity, specificity and accuracy of different methods were calculated according to final diagnosis. The sensitivity, specificity and accuracy were, respectively, 77.8%, 43.8% and 53.0% for the cut-off at 5%; 72.2%, 66.7% and 68.2% for the cut-off at 10%; 66.7%, 75.0% and 72.7% for the cut-off at 15%; 66.7%, 85.4% and 80.3% for the cut-off at 20%; 33.3%, 93.8% and 77.3% for the cut-off at 30%. BMS provided a significantly higher diagnostic performance than 5%, 10% and 15% thresholds. Conversely, we did not observe any statistically significant difference between BMS and the cut-off of more than 20%. Therefore, doubtful cases should be analysed semi-quantitatively. An increase in T/B ratio of more than 20% between delayed and late images, should be considered as a criterion of positivity, thus avoiding BMS.
Handling of Doubtful WBC Scintigraphies in Patients with Suspected Prosthetic Joint Infections / Lauri, Chiara; Lauretti, Giancarlo; Galli, Filippo; Campagna, Giuseppe; Tetti, Simone; Riolo, Donatella; Signore, Alberto. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 9:12(2020), pp. 1-13. [10.3390/jcm9124031]
Handling of Doubtful WBC Scintigraphies in Patients with Suspected Prosthetic Joint Infections
Chiara Lauri;Filippo Galli;Giuseppe CampagnaFormal Analysis
;Alberto Signore
2020
Abstract
Abstract: Despite the application of EANM recommendations for radiolabelled white-blood-cells (WBC) scintigraphy, some cases still remain doubtful based only on visual analysis. The aim of this study was to investigate the role of semi-quantitative analysis and bone marrow scan (BMS) in solving doubtful cases. We retrospectively evaluated all [99mTc]HMPAO-WBC scintigraphies performed, in the last 7 years, for a suspected monolateral prosthetic joint infection (PJI). In doubtful cases, we used five different thresholds of increase of target-to-background (T/B) ratio, between delayed and late images, as criteria of positivity (5%, 10%, 15%, 20% and 30%). BMS were also analysed and sensitivity, specificity and accuracy of different methods were calculated according to final diagnosis. The sensitivity, specificity and accuracy were, respectively, 77.8%, 43.8% and 53.0% for the cut-off at 5%; 72.2%, 66.7% and 68.2% for the cut-off at 10%; 66.7%, 75.0% and 72.7% for the cut-off at 15%; 66.7%, 85.4% and 80.3% for the cut-off at 20%; 33.3%, 93.8% and 77.3% for the cut-off at 30%. BMS provided a significantly higher diagnostic performance than 5%, 10% and 15% thresholds. Conversely, we did not observe any statistically significant difference between BMS and the cut-off of more than 20%. Therefore, doubtful cases should be analysed semi-quantitatively. An increase in T/B ratio of more than 20% between delayed and late images, should be considered as a criterion of positivity, thus avoiding BMS.File | Dimensione | Formato | |
---|---|---|---|
Lauri_Handling-of Doubtful-WBC_2020.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
2.05 MB
Formato
Adobe PDF
|
2.05 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.