Lithium-ion batteries (LIBs) are employed when high energy and power density are required. However, under electrical, mechanical, or thermal abuse conditions a thermal runaway can occur resulting in an uncontrollable increase in pressure and temperature that can lead to fire and/or explosion, and projection of fragments. In this work, the behavior of LIBs under thermal abuse conditions is analyzed. To this purpose, tests on NCA 18,650 cells are performed in a cone calorimeter by changing the radiative heat flux of the conical heater and the State of Charge (SoC) of the cells from full charge to deep discharge. The dependence of SoC and radiative heat flux on the thermal runaway onset is clearly revealed. In particular, a deep discharge determines an earlier thermal runaway of the cell with respect to those at 50% and 100% of SoC when exposed to high radiative heat flux (50 kW/m2). This is due to a mechanism such as an electrical abuse. Cell components before and after tests are investigated using Differential Scanning Calorimetry (DSC), Scanning Electron Microscopy—Energy Dispersive X-ray Spectroscopy (SEM-EDS) and X-ray Diffraction (XRD) to determine the structural, morphological, and compositional changes. It results that the first reaction (423–443 K) that occurs at the anode involves the decomposition of the electrolyte. This reaction justifies the observed earlier venting and thermal runaway of fully charged cells with respect to half-charged ones due to a greater availability of lithium which allows a faster kinetics of the reaction. In the cathode residues, metallic nickel and NO are found, given by decomposition of metal oxide by the rock-salt phase cathode.

Thermal abuse tests on 18650 Li-Ion cells using a cone calorimeter and cell residues analysis / Mele, M. L.; Bracciale, M. P.; Ubaldi, S.; Santarelli, M. L.; Mazzaro, M.; Di Bari, C.; Russo, P.. - In: ENERGIES. - ISSN 1996-1073. - 15:7(2022). [10.3390/en15072628]

Thermal abuse tests on 18650 Li-Ion cells using a cone calorimeter and cell residues analysis

Mele M. L.
Primo
Writing – Original Draft Preparation
;
Bracciale M. P.
Secondo
Investigation
;
Ubaldi S.
Writing – Review & Editing
;
Santarelli M. L.
Supervision
;
Russo P.
Ultimo
Conceptualization
2022

Abstract

Lithium-ion batteries (LIBs) are employed when high energy and power density are required. However, under electrical, mechanical, or thermal abuse conditions a thermal runaway can occur resulting in an uncontrollable increase in pressure and temperature that can lead to fire and/or explosion, and projection of fragments. In this work, the behavior of LIBs under thermal abuse conditions is analyzed. To this purpose, tests on NCA 18,650 cells are performed in a cone calorimeter by changing the radiative heat flux of the conical heater and the State of Charge (SoC) of the cells from full charge to deep discharge. The dependence of SoC and radiative heat flux on the thermal runaway onset is clearly revealed. In particular, a deep discharge determines an earlier thermal runaway of the cell with respect to those at 50% and 100% of SoC when exposed to high radiative heat flux (50 kW/m2). This is due to a mechanism such as an electrical abuse. Cell components before and after tests are investigated using Differential Scanning Calorimetry (DSC), Scanning Electron Microscopy—Energy Dispersive X-ray Spectroscopy (SEM-EDS) and X-ray Diffraction (XRD) to determine the structural, morphological, and compositional changes. It results that the first reaction (423–443 K) that occurs at the anode involves the decomposition of the electrolyte. This reaction justifies the observed earlier venting and thermal runaway of fully charged cells with respect to half-charged ones due to a greater availability of lithium which allows a faster kinetics of the reaction. In the cathode residues, metallic nickel and NO are found, given by decomposition of metal oxide by the rock-salt phase cathode.
2022
cone calorimeter; DSC; lithium-ion cell; over-discharge; SEM-EDS; SoC; thermal runaway; XRD
01 Pubblicazione su rivista::01a Articolo in rivista
Thermal abuse tests on 18650 Li-Ion cells using a cone calorimeter and cell residues analysis / Mele, M. L.; Bracciale, M. P.; Ubaldi, S.; Santarelli, M. L.; Mazzaro, M.; Di Bari, C.; Russo, P.. - In: ENERGIES. - ISSN 1996-1073. - 15:7(2022). [10.3390/en15072628]
File allegati a questo prodotto
File Dimensione Formato  
Mele_Thermal-abuse-tests_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.83 MB
Formato Adobe PDF
4.83 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1638196
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact