An innovative reinforced damp proof course, the RCW seismic dissipator, is hereby proposed. An application has been performed in a masonry building for council housing estate with 42 flats. It consists of a course between foundation and ground floor made by 3-4 mm glued foil overlapped by 60 mm layer of weak mortar, reinforced by several couples of vertical steel bars. In case of low seismic actions, the RCW ensures a connection between basement and ground floor; in case of strong motions, the damage of weak mortar layer allows relative displacements dissipating energy by friction mechanism, while vertical steel bars furnish elastic restoring force to lead back the building to the initial position after the earthquake. Tests are performed on two couple of specimens (40×60×30 cm) through series of quasi-static time histories with increasing intensity: high-strength tensioned tendons simulate vertical loads applying different compression levels to the RCW. Trials showed the self-centering performance of the RCW and the wide hysteretic behaviour. The increase of seismic performance to the buildings obtained by the RCW has been evaluated by way of numerical models: the results are presented in terms of behaviour factor q.

AN APPLICATION OF THE RCW SEISMIC DISSIPATOR ON MASONRY BUILDINGS: ON-SITE TESTING AND STRUCTURAL ANALYSIS / Andreini, M; DE FALCO, A; Giresini, L; Lombardi, F; Sassu, M. - (2013). (Intervento presentato al convegno 12th Canadian Masonry Symposium tenutosi a Vancouver, British Columbia).

AN APPLICATION OF THE RCW SEISMIC DISSIPATOR ON MASONRY BUILDINGS: ON-SITE TESTING AND STRUCTURAL ANALYSIS

GIRESINI L;
2013

Abstract

An innovative reinforced damp proof course, the RCW seismic dissipator, is hereby proposed. An application has been performed in a masonry building for council housing estate with 42 flats. It consists of a course between foundation and ground floor made by 3-4 mm glued foil overlapped by 60 mm layer of weak mortar, reinforced by several couples of vertical steel bars. In case of low seismic actions, the RCW ensures a connection between basement and ground floor; in case of strong motions, the damage of weak mortar layer allows relative displacements dissipating energy by friction mechanism, while vertical steel bars furnish elastic restoring force to lead back the building to the initial position after the earthquake. Tests are performed on two couple of specimens (40×60×30 cm) through series of quasi-static time histories with increasing intensity: high-strength tensioned tendons simulate vertical loads applying different compression levels to the RCW. Trials showed the self-centering performance of the RCW and the wide hysteretic behaviour. The increase of seismic performance to the buildings obtained by the RCW has been evaluated by way of numerical models: the results are presented in terms of behaviour factor q.
2013
12th Canadian Masonry Symposium
base dissipator; on-site testing; RCW; seismic behaviour
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
AN APPLICATION OF THE RCW SEISMIC DISSIPATOR ON MASONRY BUILDINGS: ON-SITE TESTING AND STRUCTURAL ANALYSIS / Andreini, M; DE FALCO, A; Giresini, L; Lombardi, F; Sassu, M. - (2013). (Intervento presentato al convegno 12th Canadian Masonry Symposium tenutosi a Vancouver, British Columbia).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1635947
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact