This paper provides a contribution to the rocking analysis of masonry walls by making a comparison with the kinematic analysis suggested by the Italian code. It is shown that the latter approach is generally over-conservative and therefore potentially inappropriate for historic buildings, where rehabilitation can be expensive and can affect their cultural value. The equation of motion given by the Housner formulation, corresponding to the movement of a rigid block, is here modified to account for different boundary conditions at different heights of the wall. These boundary conditions or horizontal restraints can represent vaults, transverse walls, or retrofitting devices such as steel tie-rods. A systemic analysis of walls having different dimensions and slenderness is performed, and the results from the Italian code and rocking analysis are compared. Finally, the improvement in the response offered by retrofitting devices is discussed in terms of reduction of amplitude ratio.

Comparison between rocking analysis and kinematic analysis for the dynamic out-of-plane behavior of masonry walls / Giresini, Linda; Fragiacomo, Massimo; Lourenço, Paulo B.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 44:13(2015), pp. 2359-2376. [10.1002/eqe.2592]

Comparison between rocking analysis and kinematic analysis for the dynamic out-of-plane behavior of masonry walls

GIRESINI, LINDA;
2015

Abstract

This paper provides a contribution to the rocking analysis of masonry walls by making a comparison with the kinematic analysis suggested by the Italian code. It is shown that the latter approach is generally over-conservative and therefore potentially inappropriate for historic buildings, where rehabilitation can be expensive and can affect their cultural value. The equation of motion given by the Housner formulation, corresponding to the movement of a rigid block, is here modified to account for different boundary conditions at different heights of the wall. These boundary conditions or horizontal restraints can represent vaults, transverse walls, or retrofitting devices such as steel tie-rods. A systemic analysis of walls having different dimensions and slenderness is performed, and the results from the Italian code and rocking analysis are compared. Finally, the improvement in the response offered by retrofitting devices is discussed in terms of reduction of amplitude ratio.
2015
Façade; Historical buildings; Kinematic analysis; Macro-element; Masonry; Rocking; Earth and Planetary Sciences (miscellaneous); Geotechnical Engineering and Engineering Geology
01 Pubblicazione su rivista::01a Articolo in rivista
Comparison between rocking analysis and kinematic analysis for the dynamic out-of-plane behavior of masonry walls / Giresini, Linda; Fragiacomo, Massimo; Lourenço, Paulo B.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 44:13(2015), pp. 2359-2376. [10.1002/eqe.2592]
File allegati a questo prodotto
File Dimensione Formato  
Giresini_Comparison_2015.PDF

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 2.1 MB
Formato Adobe PDF
2.1 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1635941
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 42
social impact