In this work, numerical analyses on the Volterra’s ancient walls are performed to understand the causes of a collapse occurred after an extreme rainfall (2014) and to identify the mechanical parameters that most influenced it. The stretch of collapsed wall is modelled with finite elements by distinguishing the material composing the multi-leaf wall. Non-linear static analyses are carried out with the DIANA software considering different levels of hydraulic head up to reach the collapse of the structure. The impact on the failure modes of the involved parameters, such as tensile strength, fracture energy and shear strength, are discussed. Tensile strength is found as the most relevant parameter in the failure mode. Finally, a 3-dim model is presented, and the results show a very good agreement with the failure mode actually occurred in terms of both failure modes and displacement fields. The safety evaluation is performed in the as-built and the retrofitted configuration, consisting in the wall restrained by tie-rods. The results show a significant increasing of the safety level of the retrofitted configuration showing a considerable improvement not only in terms of limit equilibrium but also in terms of structural capacity of the wall.

Estimation of tensile mechanical parameters of existing masonry through the analysis of the collapse of Volterra’s urban walls / Puppio, Ml; Giresini, L. - In: FRATTURA E INTEGRITÀ STRUTTURALE. - ISSN 1971-8993. - 13:49(2019), pp. 725-738. [10.3221/IGF-ESIS.49.65]

Estimation of tensile mechanical parameters of existing masonry through the analysis of the collapse of Volterra’s urban walls

Giresini, L
2019

Abstract

In this work, numerical analyses on the Volterra’s ancient walls are performed to understand the causes of a collapse occurred after an extreme rainfall (2014) and to identify the mechanical parameters that most influenced it. The stretch of collapsed wall is modelled with finite elements by distinguishing the material composing the multi-leaf wall. Non-linear static analyses are carried out with the DIANA software considering different levels of hydraulic head up to reach the collapse of the structure. The impact on the failure modes of the involved parameters, such as tensile strength, fracture energy and shear strength, are discussed. Tensile strength is found as the most relevant parameter in the failure mode. Finally, a 3-dim model is presented, and the results show a very good agreement with the failure mode actually occurred in terms of both failure modes and displacement fields. The safety evaluation is performed in the as-built and the retrofitted configuration, consisting in the wall restrained by tie-rods. The results show a significant increasing of the safety level of the retrofitted configuration showing a considerable improvement not only in terms of limit equilibrium but also in terms of structural capacity of the wall.
2019
numerical analyses; Volterra; collapse
01 Pubblicazione su rivista::01a Articolo in rivista
Estimation of tensile mechanical parameters of existing masonry through the analysis of the collapse of Volterra’s urban walls / Puppio, Ml; Giresini, L. - In: FRATTURA E INTEGRITÀ STRUTTURALE. - ISSN 1971-8993. - 13:49(2019), pp. 725-738. [10.3221/IGF-ESIS.49.65]
File allegati a questo prodotto
File Dimensione Formato  
Giresini_Estimation_2019.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.95 MB
Formato Adobe PDF
3.95 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1635851
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 11
social impact