The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium -decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to 10 eV ( 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter / Apponi, A.; Betti, M. G.; Borghesi, M.; Canci, N.; Cavoto, G.; Chang, C.; Chung, W.; Cocco, A. G.; Colijn, A. P.; D'Ambrosio, N.; de Groot, N.; Faverzani, M.; Ferella, A.; Ferri, E.; Ficcadenti, L.; Gariazzo, S.; Gatti, F.; Gentile, C.; Giachero, A.; Hochberg, Y.; Kahn, Y.; Kievsky, A.; Lisanti, M.; Mangano, G.; Marcucci, L. E.; Mariani, C.; Messina, M.; Monticone, E.; Nucciotti, A.; Orlandi, D.; Pandolfi, F.; Parlati, S.; Pérez de los Heros, C.; Pisanti, O.; Polosa, A. D.; Puiu, A.; Rago, I.; Raitses, Y.; Rajteri, M.; Rossi, N.; Rozwadowska, K.; Ruocco, A.; Strid, C. F.; Tan, A.; Tully, C. G.; Viviani, M.; Zeitler, U.; Zhao, F.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:05(2022), p. P05021. [10.1088/1748-0221/17/05/P05021]

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

Apponi, A.;Betti, M. G.;Borghesi, M.;Cavoto, G.;D'Ambrosio, N.;Ficcadenti, L.;Giachero, A.;Mariani, C.;Polosa, A. D.;
2022

Abstract

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium -decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to 10 eV ( 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy
2022
Mass spectrometers; Neutrino detectors; Particle detectors; Very low-energy charged particle detectors
01 Pubblicazione su rivista::01a Articolo in rivista
Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter / Apponi, A.; Betti, M. G.; Borghesi, M.; Canci, N.; Cavoto, G.; Chang, C.; Chung, W.; Cocco, A. G.; Colijn, A. P.; D'Ambrosio, N.; de Groot, N.; Faverzani, M.; Ferella, A.; Ferri, E.; Ficcadenti, L.; Gariazzo, S.; Gatti, F.; Gentile, C.; Giachero, A.; Hochberg, Y.; Kahn, Y.; Kievsky, A.; Lisanti, M.; Mangano, G.; Marcucci, L. E.; Mariani, C.; Messina, M.; Monticone, E.; Nucciotti, A.; Orlandi, D.; Pandolfi, F.; Parlati, S.; Pérez de los Heros, C.; Pisanti, O.; Polosa, A. D.; Puiu, A.; Rago, I.; Raitses, Y.; Rajteri, M.; Rossi, N.; Rozwadowska, K.; Ruocco, A.; Strid, C. F.; Tan, A.; Tully, C. G.; Viviani, M.; Zeitler, U.; Zhao, F.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 17:05(2022), p. P05021. [10.1088/1748-0221/17/05/P05021]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1633117
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact