Operation and maintenance (O&M) and monitoring strategies are important for safeguarding optimum photovoltaic (PV) performance while also minimizing downtimes due to faults. An O&M decision support system (DSS) was developed in this work for providing recommendations of actionable decisions to resolve fault and performance loss events. The proposed DSS operates entirely on raw field measurements and incorporates technical asset and financial management features. Historical measurements from a large-scale PV system installed in Greece were used for the benchmarking procedure. The results demonstrated the financial benefits of performing mitigation actions in case of near zero power production incidents. Stochastic simulations that consider component malfunctions and failures exhibited a net economic gain of approximately 4.17 e/kW/year when performing O&M actions. For an electricity price of 59.98 e/MWh, a minimum of 8.4% energy loss per year is required for offsetting the annualized O&M cost value of 7.45 e/kW/year calculated by the SunSpec/National Renewable Energy Laboratory (NREL) PV O&M Cost Model.

Operation and maintenance decision support system for photovoltaic systems / Livera, Andreas; Theristis, Marios; Micheli, Leonardo; Fernandez, Eduardo F.; Stein, Joshua S.; Georghiou, George E.. - In: IEEE ACCESS. - ISSN 2169-3536. - 10:(2022), pp. 42481-42496. [10.1109/ACCESS.2022.3168140]

Operation and maintenance decision support system for photovoltaic systems

Micheli, Leonardo;
2022

Abstract

Operation and maintenance (O&M) and monitoring strategies are important for safeguarding optimum photovoltaic (PV) performance while also minimizing downtimes due to faults. An O&M decision support system (DSS) was developed in this work for providing recommendations of actionable decisions to resolve fault and performance loss events. The proposed DSS operates entirely on raw field measurements and incorporates technical asset and financial management features. Historical measurements from a large-scale PV system installed in Greece were used for the benchmarking procedure. The results demonstrated the financial benefits of performing mitigation actions in case of near zero power production incidents. Stochastic simulations that consider component malfunctions and failures exhibited a net economic gain of approximately 4.17 e/kW/year when performing O&M actions. For an electricity price of 59.98 e/MWh, a minimum of 8.4% energy loss per year is required for offsetting the annualized O&M cost value of 7.45 e/kW/year calculated by the SunSpec/National Renewable Energy Laboratory (NREL) PV O&M Cost Model.
2022
condition monitoring; corrective actions; data analysis; fault detection and diagnosis; operation and maintenance; performance evaluation; performance loss; photovoltaics
01 Pubblicazione su rivista::01a Articolo in rivista
Operation and maintenance decision support system for photovoltaic systems / Livera, Andreas; Theristis, Marios; Micheli, Leonardo; Fernandez, Eduardo F.; Stein, Joshua S.; Georghiou, George E.. - In: IEEE ACCESS. - ISSN 2169-3536. - 10:(2022), pp. 42481-42496. [10.1109/ACCESS.2022.3168140]
File allegati a questo prodotto
File Dimensione Formato  
Livera_Operation_2022.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.95 MB
Formato Adobe PDF
1.95 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1630702
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 9
social impact