Background: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. Methods: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. Results: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. Conclusions: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.

A mobile app for improving the compliance with remote management of patients with cardiac implantable devices. a multicenter evaluation in clinical practice / Lavalle, Carlo; Magnocavallo, Michele; Bernardini, Alessia; Vetta, Giampaolo; Bianchi, Valter; Mattera, Agostino; Valerio Mariani, Marco; Ammendola, Ernesto; Busacca, Giuseppe; Piro, Agostino; Adduci, Carmen; Cal(`(o)), Leonardo; Panchetti, Luca; Viani, Stefano; Rapacciuolo, Antonio; Sanna, Giampaolo; Molon, Giulio; Quartieri, Fabio; Di Rosa, Rita; Campari, Monica; Valsecchi, Sergio; D'Onofrio, Antonio. - In: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY. - ISSN 1383-875X. - 64:1(2022), pp. 257-264. [10.1007/s10840-022-01207-y]

A mobile app for improving the compliance with remote management of patients with cardiac implantable devices. a multicenter evaluation in clinical practice

Carlo Lavalle
Primo
;
Michele Magnocavallo
Secondo
;
Alessia Bernardini;Agostino Piro;Carmen Adduci;
2022

Abstract

Background: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. Methods: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. Results: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. Conclusions: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.
2022
cardiac implantable electronic device; follow-up; mobile app; remote monitoring
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
A mobile app for improving the compliance with remote management of patients with cardiac implantable devices. a multicenter evaluation in clinical practice / Lavalle, Carlo; Magnocavallo, Michele; Bernardini, Alessia; Vetta, Giampaolo; Bianchi, Valter; Mattera, Agostino; Valerio Mariani, Marco; Ammendola, Ernesto; Busacca, Giuseppe; Piro, Agostino; Adduci, Carmen; Cal(`(o)), Leonardo; Panchetti, Luca; Viani, Stefano; Rapacciuolo, Antonio; Sanna, Giampaolo; Molon, Giulio; Quartieri, Fabio; Di Rosa, Rita; Campari, Monica; Valsecchi, Sergio; D'Onofrio, Antonio. - In: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY. - ISSN 1383-875X. - 64:1(2022), pp. 257-264. [10.1007/s10840-022-01207-y]
File allegati a questo prodotto
File Dimensione Formato  
Lavalle_Mobile_2022.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 895.13 kB
Formato Adobe PDF
895.13 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1629224
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact