The presentwork analyses, for the first time, the heat transfer frompin micro-fins. The scope of the present paper is comparing thermal performance of plate micro-fin and pin micro-fin arrays under natural convection conditionsin air.Two fin geometries are considered: plate and pin fin arrayswith the same thermal exchanging surfaceare tested. The investigation shows that the pin micro-fins can improve the thermal performance compared toplate micro-fin arrays. Indeed, pin micro-fins are found to have higher heat transfer coefficients and lower thermalresistances, as well as a better material usage. This makes pin micro-fins able to achieve both thermal enhancementand weight reduction than plate micro-fins. The radiative heat transfer is also calculated: A new model to determine the radiative view factors of pin fins is proposed and is used in the analysis. The effect of the orientation is considered as well.

Experimental comparison of micro-scaled plate-fins and pin-fins under natural convection / Micheli, L.; Reddy, K. S.; Mallick, T. K.. - In: INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER. - ISSN 0735-1933. - 75:(2016), pp. 59-66. [10.1016/j.icheatmasstransfer.2016.03.023]

Experimental comparison of micro-scaled plate-fins and pin-fins under natural convection

Micheli L.;
2016

Abstract

The presentwork analyses, for the first time, the heat transfer frompin micro-fins. The scope of the present paper is comparing thermal performance of plate micro-fin and pin micro-fin arrays under natural convection conditionsin air.Two fin geometries are considered: plate and pin fin arrayswith the same thermal exchanging surfaceare tested. The investigation shows that the pin micro-fins can improve the thermal performance compared toplate micro-fin arrays. Indeed, pin micro-fins are found to have higher heat transfer coefficients and lower thermalresistances, as well as a better material usage. This makes pin micro-fins able to achieve both thermal enhancementand weight reduction than plate micro-fins. The radiative heat transfer is also calculated: A new model to determine the radiative view factors of pin fins is proposed and is used in the analysis. The effect of the orientation is considered as well.
2016
experimental; micro fins; natural convection; pin fin; plate fin
01 Pubblicazione su rivista::01a Articolo in rivista
Experimental comparison of micro-scaled plate-fins and pin-fins under natural convection / Micheli, L.; Reddy, K. S.; Mallick, T. K.. - In: INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER. - ISSN 0735-1933. - 75:(2016), pp. 59-66. [10.1016/j.icheatmasstransfer.2016.03.023]
File allegati a questo prodotto
File Dimensione Formato  
Micheli_Experimental comparison_2016.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.07 MB
Formato Adobe PDF
1.07 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1625597
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 33
social impact