BACKGROUND & AIMS: One-fourth of colorectal neoplasias are missed during screening colonoscopies; these can develop into colorectal cancer (CRC). Deep learning systems allow for real-time computer-aided detection (CADe) of polyps with high accuracy. We performed a multicenter, randomized trial to assess the safety and efficacy of a CADe system in detection of colorectal neoplasias during real-time colonoscopy. METHODS: We analyzed data from 685 subjects (61.32 ± 10.2 years old; 337 men) undergoing screening colonoscopies for CRC, post-polypectomy surveillance, or workup due to positive results from a fecal immunochemical test or signs or symptoms of CRC, at 3 centers in Italy from September through November 2019. Patients were randomly assigned (1:1) to groups who underwent high-definition colonoscopies with the CADe system or without (controls). The CADe system included an artificial intelligence-based medical device (GI-Genius, Medtronic) trained to process colonoscopy images and superimpose them, in real time, on the endoscopy display a green box over suspected lesions. A minimum withdrawal time of 6 minutes was required. Lesions were collected and histopathology findings were used as the reference standard. The primary outcome was adenoma detection rate (ADR, the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, non-neoplastic resection rate, and withdrawal time. RESULTS: The ADR was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk [RR], 1.30; 95% confidence interval [CI], 1.14-1.45). Adenomas detected per colonoscopy were significantly higher in the CADe group (mean, 1.07 ±1.54) than in the control group (mean 0.71 ± 1.20) (incidence rate ratio, 1.46; 95% CI, 1.15-1.86). Adenomas 5 mm or smaller were detected in a significantly higher proportion of subjects in the CADe group (33.7%) than in the control group (26.5%; RR, 1.26; 95% CI, 1.01-1.52), as were adenomas of 6 to 9 mm (detected in 10.6% of subjects in the CADe group vs 5.8% in the control group; RR, 1.78; 95% CI, 1.09-2.86), regardless of morphology or location. There was no significant difference between groups in withdrawal time (417 ± 101 seconds for the CADe group vs 435 ± 149 for controls; P = .1) or proportion of subjects with resection of non-neoplastic lesions (26.0% in the CADe group vs 28.7% of controls; RR, 1.00; 95% CI, 0.90-1.12). CONCLUSIONS: In a multicenter, randomized trial, we found that including CADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy without increasing withdrawal time. ClinicalTrials.gov no: 04079478.

Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial / Repici, A; Badalamenti, M; Maselli, R; Correale, L; Radaelli, F; Rondonotti, E; Ferrara, E; Spadaccini, M; Alkandari, A; Fugazza, A; Anderloni, A; Galtieri, Pa; Pellegatta, G; Carrara, S; Di Leo, M; Craviotto, V; Lamonaca, L; Lorenzetti, R; Andrealli, A; Antonelli, G; Wallace, M; Sharma, P; Rosch, T; Hassan, C. - In: GASTROENTEROLOGY. - ISSN 0016-5085. - 8:10(2020), pp. 1-6. [10.1053/j.gastro.2020.04.062]

Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial

Antonelli G;
2020

Abstract

BACKGROUND & AIMS: One-fourth of colorectal neoplasias are missed during screening colonoscopies; these can develop into colorectal cancer (CRC). Deep learning systems allow for real-time computer-aided detection (CADe) of polyps with high accuracy. We performed a multicenter, randomized trial to assess the safety and efficacy of a CADe system in detection of colorectal neoplasias during real-time colonoscopy. METHODS: We analyzed data from 685 subjects (61.32 ± 10.2 years old; 337 men) undergoing screening colonoscopies for CRC, post-polypectomy surveillance, or workup due to positive results from a fecal immunochemical test or signs or symptoms of CRC, at 3 centers in Italy from September through November 2019. Patients were randomly assigned (1:1) to groups who underwent high-definition colonoscopies with the CADe system or without (controls). The CADe system included an artificial intelligence-based medical device (GI-Genius, Medtronic) trained to process colonoscopy images and superimpose them, in real time, on the endoscopy display a green box over suspected lesions. A minimum withdrawal time of 6 minutes was required. Lesions were collected and histopathology findings were used as the reference standard. The primary outcome was adenoma detection rate (ADR, the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, non-neoplastic resection rate, and withdrawal time. RESULTS: The ADR was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk [RR], 1.30; 95% confidence interval [CI], 1.14-1.45). Adenomas detected per colonoscopy were significantly higher in the CADe group (mean, 1.07 ±1.54) than in the control group (mean 0.71 ± 1.20) (incidence rate ratio, 1.46; 95% CI, 1.15-1.86). Adenomas 5 mm or smaller were detected in a significantly higher proportion of subjects in the CADe group (33.7%) than in the control group (26.5%; RR, 1.26; 95% CI, 1.01-1.52), as were adenomas of 6 to 9 mm (detected in 10.6% of subjects in the CADe group vs 5.8% in the control group; RR, 1.78; 95% CI, 1.09-2.86), regardless of morphology or location. There was no significant difference between groups in withdrawal time (417 ± 101 seconds for the CADe group vs 435 ± 149 for controls; P = .1) or proportion of subjects with resection of non-neoplastic lesions (26.0% in the CADe group vs 28.7% of controls; RR, 1.00; 95% CI, 0.90-1.12). CONCLUSIONS: In a multicenter, randomized trial, we found that including CADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy without increasing withdrawal time. ClinicalTrials.gov no: 04079478.
2020
01 Pubblicazione su rivista::01a Articolo in rivista
Efficacy of Real-Time Computer-Aided Detection of Colorectal Neoplasia in a Randomized Trial / Repici, A; Badalamenti, M; Maselli, R; Correale, L; Radaelli, F; Rondonotti, E; Ferrara, E; Spadaccini, M; Alkandari, A; Fugazza, A; Anderloni, A; Galtieri, Pa; Pellegatta, G; Carrara, S; Di Leo, M; Craviotto, V; Lamonaca, L; Lorenzetti, R; Andrealli, A; Antonelli, G; Wallace, M; Sharma, P; Rosch, T; Hassan, C. - In: GASTROENTEROLOGY. - ISSN 0016-5085. - 8:10(2020), pp. 1-6. [10.1053/j.gastro.2020.04.062]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1622785
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 337
  • ???jsp.display-item.citation.isi??? 291
social impact