Context: Holmium laser enucleation of the prostate (HoLEP) is currently the size-independent gold standard for surgical treatment of benign prostate enlargement (BPE). Objective: To systematically review the current literature and compare perioperative parameters, early outcomes, and complications after HoLEP with MOSES technology LEP (MoLEP) for BPE. Evidence acquisition: This study was performed according to the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) framework using the PICOS (Patient, Intervention Comparison, Outcome, Study) model to frame the clinical question. The population was adults undergoing LEP for BPE, with standard HoLEP as the intervention and MoLEP as the comparison. The outcomes were enucleation time, surgical time, haemostasis time, energy used, hospital length of stay (LOS), recatheterisation, urethral stricture rate, and functional outcomes. The study type included randomised, prospective nonrandomised, and retrospective studies. Evidence synthesis: Seven studies were included for meta-analysis after screening. Mean enucleation time was significantly shorter for MoLEP (mean difference [MD] −7.27 min, 95% confidence interval [CI] −11.26 to −3.28; p = 0.0004). Postoperative LOS was significantly longer in the HoLEP group (MD 0.3 d, 95% CI -0.24-0.85,p<0.0001). Although not statistically significant, there was a trend for higher incidence of recatheterisation (odds ratio [OR] 1.39, 95% CI 0.47–4.09; p = 0.55) and urethral stricture (OR 1.81, 95% CI 0.45–7.37; p = 0.41) in the HoLEP group. The mean maximum peak flow favoured HoLEP (MD 0.95 ml/s, 95% CI −1.66 to 3.57; p = 0.47) and a lower mean postvoid residual volume was noted in the MoLEP group (MD −10.08 ml, 95% CI −53.54 to 33.37; p = 0.65). Conclusions: MoLEP performed better in terms of intraoperative outcomes compared to standard HoLEP, resulting in shorter enucleation, haemostasis, and total surgical times for similar energy delivered. In addition, postoperative LOS with an early trial of catheter favours MoLEP, making it appealing as a day surgery procedure. Patient summary: We reviewed the literature for early outcomes of laser treatment of the prostate for tissue removal using a MOSES system in comparison to standard treatment with a holmium laser for BPE. We found that the MOSES laser system can improve intraoperative performance, making prostate treatment a same-day discharge surgery.

Does MOSES Technology Enhance the Efficiency and Outcomes of Standard Holmium Laser Enucleation of the Prostate? Results of a Systematic Review and Meta-analysis of Comparative Studies / Gauhar, V.; Gilling, P.; Pirola, G. M.; Chan, V. W. -S.; Lim, E. J.; Maggi, M.; Teoh, J. Y. -C.; Krambeck, A.; Castellani, D.. - In: EUROPEAN UROLOGY FOCUS. - ISSN 2405-4569. - (2022). [10.1016/j.euf.2022.01.013]

Does MOSES Technology Enhance the Efficiency and Outcomes of Standard Holmium Laser Enucleation of the Prostate? Results of a Systematic Review and Meta-analysis of Comparative Studies

Maggi M.;
2022

Abstract

Context: Holmium laser enucleation of the prostate (HoLEP) is currently the size-independent gold standard for surgical treatment of benign prostate enlargement (BPE). Objective: To systematically review the current literature and compare perioperative parameters, early outcomes, and complications after HoLEP with MOSES technology LEP (MoLEP) for BPE. Evidence acquisition: This study was performed according to the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) framework using the PICOS (Patient, Intervention Comparison, Outcome, Study) model to frame the clinical question. The population was adults undergoing LEP for BPE, with standard HoLEP as the intervention and MoLEP as the comparison. The outcomes were enucleation time, surgical time, haemostasis time, energy used, hospital length of stay (LOS), recatheterisation, urethral stricture rate, and functional outcomes. The study type included randomised, prospective nonrandomised, and retrospective studies. Evidence synthesis: Seven studies were included for meta-analysis after screening. Mean enucleation time was significantly shorter for MoLEP (mean difference [MD] −7.27 min, 95% confidence interval [CI] −11.26 to −3.28; p = 0.0004). Postoperative LOS was significantly longer in the HoLEP group (MD 0.3 d, 95% CI -0.24-0.85,p<0.0001). Although not statistically significant, there was a trend for higher incidence of recatheterisation (odds ratio [OR] 1.39, 95% CI 0.47–4.09; p = 0.55) and urethral stricture (OR 1.81, 95% CI 0.45–7.37; p = 0.41) in the HoLEP group. The mean maximum peak flow favoured HoLEP (MD 0.95 ml/s, 95% CI −1.66 to 3.57; p = 0.47) and a lower mean postvoid residual volume was noted in the MoLEP group (MD −10.08 ml, 95% CI −53.54 to 33.37; p = 0.65). Conclusions: MoLEP performed better in terms of intraoperative outcomes compared to standard HoLEP, resulting in shorter enucleation, haemostasis, and total surgical times for similar energy delivered. In addition, postoperative LOS with an early trial of catheter favours MoLEP, making it appealing as a day surgery procedure. Patient summary: We reviewed the literature for early outcomes of laser treatment of the prostate for tissue removal using a MOSES system in comparison to standard treatment with a holmium laser for BPE. We found that the MOSES laser system can improve intraoperative performance, making prostate treatment a same-day discharge surgery.
2022
Holmium laser enucleation of the prostate; Laser therapy; Lower urinary tract symptoms; Prostatic hyperplasia
01 Pubblicazione su rivista::01a Articolo in rivista
Does MOSES Technology Enhance the Efficiency and Outcomes of Standard Holmium Laser Enucleation of the Prostate? Results of a Systematic Review and Meta-analysis of Comparative Studies / Gauhar, V.; Gilling, P.; Pirola, G. M.; Chan, V. W. -S.; Lim, E. J.; Maggi, M.; Teoh, J. Y. -C.; Krambeck, A.; Castellani, D.. - In: EUROPEAN UROLOGY FOCUS. - ISSN 2405-4569. - (2022). [10.1016/j.euf.2022.01.013]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1619232
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 26
social impact