Catheter ablation is a well-established therapeutic option for management of recurrent ventricular tachycardia in patients with ischemic/non-ischemic heart disease and procedural complications include a mortality rate of up to 3% and a risk of major complications up to 10%. Cardiac perforation following a catheter ablation is rare but serious complication and occurs in 1% of ventricular ablation procedures. The appropriate surgical repair may be challenging and need cardiopulmonary bypass support according to the location of the lesion and the hemodynamic status of the patient. We report the case of a free wall right ventricular perforation of the interventricular groove with cardiac tamponade following catheter ablation for recurrent ventricular tachycardia. Due to the proximity of the left anterior descending artery and the extreme fragility of tissues, the patient was treated successfully by a sutureless patch technique using a fibrin tissue-adhesive collagen fleece (TachoSil®). This technique is a safe and effective surgical option to repair a ventricular perforation especially when the ventricular tissues are fragile. It is simple and enable to realize surgical repair also if the localization of tear is difficult to access and without the need for cardiopulmonary bypass support if hemodynamic conditions are stable.

Efficacy of TachoSil® as a sutureless hemostatic patch to repair a perforation of the interventricular groove during endocardial radiofrequency ablation / Fiore, A.; Grandmougin, D.; Maureira, J. -P.; Elfarra, M.; Laurent, N.; Andronache, M.; Folliguet, T.; Villemot, J. -P.. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - 55:2(2014), pp. 295-298.

Efficacy of TachoSil® as a sutureless hemostatic patch to repair a perforation of the interventricular groove during endocardial radiofrequency ablation

Fiore A.
Primo
;
2014

Abstract

Catheter ablation is a well-established therapeutic option for management of recurrent ventricular tachycardia in patients with ischemic/non-ischemic heart disease and procedural complications include a mortality rate of up to 3% and a risk of major complications up to 10%. Cardiac perforation following a catheter ablation is rare but serious complication and occurs in 1% of ventricular ablation procedures. The appropriate surgical repair may be challenging and need cardiopulmonary bypass support according to the location of the lesion and the hemodynamic status of the patient. We report the case of a free wall right ventricular perforation of the interventricular groove with cardiac tamponade following catheter ablation for recurrent ventricular tachycardia. Due to the proximity of the left anterior descending artery and the extreme fragility of tissues, the patient was treated successfully by a sutureless patch technique using a fibrin tissue-adhesive collagen fleece (TachoSil®). This technique is a safe and effective surgical option to repair a ventricular perforation especially when the ventricular tissues are fragile. It is simple and enable to realize surgical repair also if the localization of tear is difficult to access and without the need for cardiopulmonary bypass support if hemodynamic conditions are stable.
2014
Cardiac tamponade; Cardiovascular surgical procedures hemostatic techniques; Catheter ablation
01 Pubblicazione su rivista::01a Articolo in rivista
Efficacy of TachoSil® as a sutureless hemostatic patch to repair a perforation of the interventricular groove during endocardial radiofrequency ablation / Fiore, A.; Grandmougin, D.; Maureira, J. -P.; Elfarra, M.; Laurent, N.; Andronache, M.; Folliguet, T.; Villemot, J. -P.. - In: JOURNAL OF CARDIOVASCULAR SURGERY. - ISSN 0021-9509. - 55:2(2014), pp. 295-298.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1618272
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact