The Argentinean Andean region hosts a vast geothermal resource clustered by active magmatic and tectonic activity. One of the most studied geothermal areas is the Tuzgle-Tocomar geothermal system in Central Puna (NW Argentina). However, despite the existence of several studies since the 1970′s highlighting the geothermal potential of the area, only highly schematic and dissimilar conceptual models have been proposed for the Tocomar Geothermal System. This study presents new detailed geological-structural and hydrogeochemical data, together with in-situ permeability analysis of fault zones and Raman spectroscopic characterization of hydrothermal-alteration minerals. The electrical generating capacity has also been evaluated using the volumetric method and a stochastic approach. A new comprehensive conceptual model of the studied area was constructed highlighting the role of the Calama-Olacapato-El Toro (COT) fault-system in the circulation of hydrothermal fluids. The reservoir of the Tocomar geothermal system has a Na+-Clˉ(HCO3)ˉ composition and an estimated temperature of ∼235 °C. Such a reservoir is hosted in fractured Ordovician rocks and controlled by the COT-like Chorrillos transpressive fault at 1000–1500 m depth b.g.l. The water isotopic data and hydrological features indicate a regional recharge beyond the Tocomar sub-basin boundaries (>5000 m a.s.l.). Additionally, the main hydrothermal reservoir receives inputs of magmatic fluids from the degassing of the intra-crustal rhyolitic magma chamber of the Tocomar volcanic center. The Monte Carlo simulations suggest that the Tocomar geothermal system has a probable power production capacity above 1.23 MWe (P90), 6.18 MWe (P50) and 11.67 MWe (P10) at different confidence levels. All calculations were biased towards minimum values, thus a tighter definition of the resource size and fracture porosity would significantly impact on the predictions. Notwithstanding, the strategic position of the Tocomar geothermal field encourages move forward towards more in-depth exploration phases.

Structural analysis and fluid geochemistry as tools to assess the potential of the Tocomar geothermal system, Central Puna (Argentina) / Filipovich, R.; Chiodi, A.; Baez, W.; Ahumada, M. F.; Invernizzi, C.; Taviani, S.; Aldega, L.; Tassi, F.; Barrios, A.; Corrado, S.; Groppelli, G.; Norini, G.; Bigi, S.; Caricchi, C.; De Benedetti, A.; De Astis, G.; Becchio, R.; Viramonte, J. G.; Giordano, G.. - In: GEOTHERMICS. - ISSN 0375-6505. - 98:(2022). [10.1016/j.geothermics.2021.102297]

Structural analysis and fluid geochemistry as tools to assess the potential of the Tocomar geothermal system, Central Puna (Argentina)

Aldega L.;Bigi S.;
2022

Abstract

The Argentinean Andean region hosts a vast geothermal resource clustered by active magmatic and tectonic activity. One of the most studied geothermal areas is the Tuzgle-Tocomar geothermal system in Central Puna (NW Argentina). However, despite the existence of several studies since the 1970′s highlighting the geothermal potential of the area, only highly schematic and dissimilar conceptual models have been proposed for the Tocomar Geothermal System. This study presents new detailed geological-structural and hydrogeochemical data, together with in-situ permeability analysis of fault zones and Raman spectroscopic characterization of hydrothermal-alteration minerals. The electrical generating capacity has also been evaluated using the volumetric method and a stochastic approach. A new comprehensive conceptual model of the studied area was constructed highlighting the role of the Calama-Olacapato-El Toro (COT) fault-system in the circulation of hydrothermal fluids. The reservoir of the Tocomar geothermal system has a Na+-Clˉ(HCO3)ˉ composition and an estimated temperature of ∼235 °C. Such a reservoir is hosted in fractured Ordovician rocks and controlled by the COT-like Chorrillos transpressive fault at 1000–1500 m depth b.g.l. The water isotopic data and hydrological features indicate a regional recharge beyond the Tocomar sub-basin boundaries (>5000 m a.s.l.). Additionally, the main hydrothermal reservoir receives inputs of magmatic fluids from the degassing of the intra-crustal rhyolitic magma chamber of the Tocomar volcanic center. The Monte Carlo simulations suggest that the Tocomar geothermal system has a probable power production capacity above 1.23 MWe (P90), 6.18 MWe (P50) and 11.67 MWe (P10) at different confidence levels. All calculations were biased towards minimum values, thus a tighter definition of the resource size and fracture porosity would significantly impact on the predictions. Notwithstanding, the strategic position of the Tocomar geothermal field encourages move forward towards more in-depth exploration phases.
2022
conceptual model; fault-related; geothermal exploration; geothermal potential; Southern Central Andes
01 Pubblicazione su rivista::01a Articolo in rivista
Structural analysis and fluid geochemistry as tools to assess the potential of the Tocomar geothermal system, Central Puna (Argentina) / Filipovich, R.; Chiodi, A.; Baez, W.; Ahumada, M. F.; Invernizzi, C.; Taviani, S.; Aldega, L.; Tassi, F.; Barrios, A.; Corrado, S.; Groppelli, G.; Norini, G.; Bigi, S.; Caricchi, C.; De Benedetti, A.; De Astis, G.; Becchio, R.; Viramonte, J. G.; Giordano, G.. - In: GEOTHERMICS. - ISSN 0375-6505. - 98:(2022). [10.1016/j.geothermics.2021.102297]
File allegati a questo prodotto
File Dimensione Formato  
Filipovich _Structural_2022.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.53 MB
Formato Adobe PDF
1.53 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1617168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 13
social impact