Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients’ safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.

Artificial neural network for total laboratory automation to improve the management of sample dilution: Smart automation for clinical laboratory timeliness / Ialongo, C.; Pieri, M.; Bernardini, S.. - In: SLAS TECHNOLOGY. - ISSN 2472-6303. - 22:1(2017), pp. 44-49. [10.1177/2211068216636635]

Artificial neural network for total laboratory automation to improve the management of sample dilution: Smart automation for clinical laboratory timeliness

Ialongo C.
;
2017

Abstract

Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients’ safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.
2017
Artificial neural network; Cardiac troponin I; STAT; Total laboratory automation; Turnaround time
01 Pubblicazione su rivista::01a Articolo in rivista
Artificial neural network for total laboratory automation to improve the management of sample dilution: Smart automation for clinical laboratory timeliness / Ialongo, C.; Pieri, M.; Bernardini, S.. - In: SLAS TECHNOLOGY. - ISSN 2472-6303. - 22:1(2017), pp. 44-49. [10.1177/2211068216636635]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1611354
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 11
social impact