The transition to total automation represents the greatest leap for a clinical laboratory, characterized by a totally new philosophy of process management. We have investigated the impact of total automation on core laboratory efficiency and its effects on the clinical services related to STAT tests. For this purpose, a 47-month retrospective study based on the analysis of 44,212 records of STAT cardiac troponin I (CTNI) tests was performed. The core laboratory reached a new efficiency level 3 months after the implementation of total automation. Median turnaround time (TAT) was reduced by 14.9±1.5 min for the emergency department (p < 0.01), reaching 41.6±1.2 min. In non–emergency departments, median TAT was reduced by 19.8±2.2 min (p < 0.01), reaching 52±1.3 min. There was no change in the volume of ordered STAT CTNI tests by the emergency department (p = 0.811), whereas for non–emergency departments there was a reduction of 115.7±50 monthly requests on average (p = 0.026). The volume of ordered tests decreased only in time frames of the regular shift following the morning round. Thus, total automation significantly improves the core laboratory efficiency in terms of TAT. As a consequence, the volume of STAT tests ordered by hospital departments (except for the emergency department) decreased due to reduced duplicated requests.

Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests / Ialongo, C.; Porzio, O.; Giambini, I.; Bernardini, S.. - In: JOURNAL OF LABORATORY AUTOMATION. - ISSN 2211-0682. - 21:3(2016), pp. 451-458. [10.1177/2211068215581488]

Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests

Ialongo C.
Primo
;
2016

Abstract

The transition to total automation represents the greatest leap for a clinical laboratory, characterized by a totally new philosophy of process management. We have investigated the impact of total automation on core laboratory efficiency and its effects on the clinical services related to STAT tests. For this purpose, a 47-month retrospective study based on the analysis of 44,212 records of STAT cardiac troponin I (CTNI) tests was performed. The core laboratory reached a new efficiency level 3 months after the implementation of total automation. Median turnaround time (TAT) was reduced by 14.9±1.5 min for the emergency department (p < 0.01), reaching 41.6±1.2 min. In non–emergency departments, median TAT was reduced by 19.8±2.2 min (p < 0.01), reaching 52±1.3 min. There was no change in the volume of ordered STAT CTNI tests by the emergency department (p = 0.811), whereas for non–emergency departments there was a reduction of 115.7±50 monthly requests on average (p = 0.026). The volume of ordered tests decreased only in time frames of the regular shift following the morning round. Thus, total automation significantly improves the core laboratory efficiency in terms of TAT. As a consequence, the volume of STAT tests ordered by hospital departments (except for the emergency department) decreased due to reduced duplicated requests.
2016
cardiac troponin I; core laboratory; STAT; total laboratory automation; turnaround time
01 Pubblicazione su rivista::01a Articolo in rivista
Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests / Ialongo, C.; Porzio, O.; Giambini, I.; Bernardini, S.. - In: JOURNAL OF LABORATORY AUTOMATION. - ISSN 2211-0682. - 21:3(2016), pp. 451-458. [10.1177/2211068215581488]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1611314
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 22
social impact