An analytical procedure based on ultra-performance liquid chromatography-mass spectrometry was developed to screen and to confirm dutasteride and its metabolites in human urine. Sample preparation included an enzymatic hydrolysis followed by solid-phase extraction using the strong cation exchange cartridges OASIS® MCX. The chromatographic separation was carried out on C18 column, employing as mobile phases ultra purified water and acetonitrile, both containing 0.1% formic acid. Detection was achieved using a triple quadrupole as a mass spectrometric analyzer, with positive ion electrospray ionization and multiple reaction monitoring as acquisition mode. The analytical procedure developed was validated according to ISO 17025 and World Anti-Doping Agency guidelines. The extraction efficiency was estimated to be greater than 75% for both dutasteride and its hydroxylated metabolites. Detection capability was determined in the range of 0.1–0.4 ng/mL. Specificity and repeatability of the relative retention times (CV% < 0.5) and of the relative abundances of the characteristic ion transitions selected (CV% < 10) were confirmed to be fit for purpose to ensure the unambiguous identification of dutasteride and its metabolites in human urine. The developed method was used to characterize the urinary excretion profile of dutasteride after both chronic and acute administration of therapeutic doses. After chronic administration, dutasteride and its hydroxylated metabolites were easily detected and confirmed. After acute administration, instead, only the two hydroxylated metabolites were detected for 3–4 days.

Detection of 5α-reductase inhibitors by UPLC–MS/MS: Application to the definition of the excretion profile of dutasteride in urine / Mazzarino, M.; Martellone, L.; Comunita, F.; de la Torre, X.; Molaioni, F.; Botre, F.. - In: DRUG TESTING AND ANALYSIS. - ISSN 1942-7603. - 11:11-12(2019), pp. 1737-1746. [10.1002/dta.2702]

Detection of 5α-reductase inhibitors by UPLC–MS/MS: Application to the definition of the excretion profile of dutasteride in urine

Martellone L.
Formal Analysis
;
2019

Abstract

An analytical procedure based on ultra-performance liquid chromatography-mass spectrometry was developed to screen and to confirm dutasteride and its metabolites in human urine. Sample preparation included an enzymatic hydrolysis followed by solid-phase extraction using the strong cation exchange cartridges OASIS® MCX. The chromatographic separation was carried out on C18 column, employing as mobile phases ultra purified water and acetonitrile, both containing 0.1% formic acid. Detection was achieved using a triple quadrupole as a mass spectrometric analyzer, with positive ion electrospray ionization and multiple reaction monitoring as acquisition mode. The analytical procedure developed was validated according to ISO 17025 and World Anti-Doping Agency guidelines. The extraction efficiency was estimated to be greater than 75% for both dutasteride and its hydroxylated metabolites. Detection capability was determined in the range of 0.1–0.4 ng/mL. Specificity and repeatability of the relative retention times (CV% < 0.5) and of the relative abundances of the characteristic ion transitions selected (CV% < 10) were confirmed to be fit for purpose to ensure the unambiguous identification of dutasteride and its metabolites in human urine. The developed method was used to characterize the urinary excretion profile of dutasteride after both chronic and acute administration of therapeutic doses. After chronic administration, dutasteride and its hydroxylated metabolites were easily detected and confirmed. After acute administration, instead, only the two hydroxylated metabolites were detected for 3–4 days.
2019
anti-doping analysis; athlete biological passport; confounding factors; dutasteride; UPLC–MS/(MS); 5-alpha Reductase Inhibitors; Chromatography, High Pressure Liquid; Dutasteride; Female; Humans; Limit of Detection; Male; Spectrometry, Mass, Electrospray Ionization; Substance Abuse Detection; Tandem Mass Spectrometry
01 Pubblicazione su rivista::01a Articolo in rivista
Detection of 5α-reductase inhibitors by UPLC–MS/MS: Application to the definition of the excretion profile of dutasteride in urine / Mazzarino, M.; Martellone, L.; Comunita, F.; de la Torre, X.; Molaioni, F.; Botre, F.. - In: DRUG TESTING AND ANALYSIS. - ISSN 1942-7603. - 11:11-12(2019), pp. 1737-1746. [10.1002/dta.2702]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1610331
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact