Objectives: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery—restoration delivery (T0)—and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. Materials and Methods: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. Results: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. Conclusions: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.
Correlation between peri-implant marginal bone loss progression and peri-implant sulcular fluid levels of Metalloproteinase-8 / Guarnieri, R.; Zanza, A.; D'Angelo, M.; Di Nardo, D.; Del Giudice, A.; Mazzoni, A.; Reda, R.; Testarelli, L.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 12:1(2022). [10.3390/jpm12010058]
Correlation between peri-implant marginal bone loss progression and peri-implant sulcular fluid levels of Metalloproteinase-8
Zanza A.Secondo
Methodology
;D'angelo M.Writing – Review & Editing
;Di Nardo D.
Investigation
;Reda R.Penultimo
Investigation
;Testarelli L.Ultimo
Conceptualization
2022
Abstract
Objectives: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery—restoration delivery (T0)—and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. Materials and Methods: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. Results: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. Conclusions: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.File | Dimensione | Formato | |
---|---|---|---|
Guarnieri_Correlation_2022.pdf
accesso aperto
Note: https://www.mdpi.com/2075-4426/12/1/58
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
3.26 MB
Formato
Adobe PDF
|
3.26 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.