Introduction Crohn's disease diagnosis and monitoring remains a great clinical challenge and often requires multiple testing modalities. Assessing Crohn's disease activity in the entire gastrointestinal (GI) tract using a panenteric capsule endoscopy (CE) system could be used as an alternative to colonoscopy and cross-sectional imaging. This study assessed the accuracy and safety of panenteric CE in Crohn's disease as compared with ileocolonoscopy (IC) and/or magnetic resonance enterography (MRE). Methods A prospective, multicentre study was performed in subjects with established Crohn's disease. Individuals with proven small bowel patency underwent a standardised bowel preparation, followed by CE ingestion and IC either the same or following day. MRE, IC, and CE interpretations were performed by blinded central readers using validated scoring systems. The primary endpoint was the overall sensitivity of CE vs MRE and/or IC in Crohn's disease subjects. Results Study enrolment included 158 subjects from 21 sites in the USA, Austria, and Israel. Of those, 99 were included in the analysis. Imaging modality scores indicated none to mild inflammation in the proximal small bowel and colon, but discrepant levels of inflammation in the terminal ileum. Overall sensitivity for active enteric inflammation (CE vs MRE and/or IC) was 94% vs 100% (p=0.125) and specificity was 74% vs 22% (p=0.001). Sensitivity of CE was superior to MRE for enteric inflammation in the proximal small bowel (97% vs 71%, p=0.021), and similar to MRE and/or IC in the terminal ileum and colon (p=0.500-0.625). There were seven serious adverse advents of which three were related to the CE device. Conclusion Panenteric CE is a reliable tool for assessing Crohn's disease mucosal activity and extent compared with more invasive methods. This study demonstrates high performance of the panenteric CE as compared to MRE and/or IC without the need for multiple tests in non-stricturing Crohn's disease.

Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study / Bruining, D. H.; Oliva, S.; Fleisher, M. R.; Fischer, M.; Fletcher, J. G.. - In: BMJ OPEN GASTROENTEROLOGY. - ISSN 2054-4774. - 7:1(2020). [10.1136/bmjgast-2019-000365]

Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study

Oliva S.;
2020

Abstract

Introduction Crohn's disease diagnosis and monitoring remains a great clinical challenge and often requires multiple testing modalities. Assessing Crohn's disease activity in the entire gastrointestinal (GI) tract using a panenteric capsule endoscopy (CE) system could be used as an alternative to colonoscopy and cross-sectional imaging. This study assessed the accuracy and safety of panenteric CE in Crohn's disease as compared with ileocolonoscopy (IC) and/or magnetic resonance enterography (MRE). Methods A prospective, multicentre study was performed in subjects with established Crohn's disease. Individuals with proven small bowel patency underwent a standardised bowel preparation, followed by CE ingestion and IC either the same or following day. MRE, IC, and CE interpretations were performed by blinded central readers using validated scoring systems. The primary endpoint was the overall sensitivity of CE vs MRE and/or IC in Crohn's disease subjects. Results Study enrolment included 158 subjects from 21 sites in the USA, Austria, and Israel. Of those, 99 were included in the analysis. Imaging modality scores indicated none to mild inflammation in the proximal small bowel and colon, but discrepant levels of inflammation in the terminal ileum. Overall sensitivity for active enteric inflammation (CE vs MRE and/or IC) was 94% vs 100% (p=0.125) and specificity was 74% vs 22% (p=0.001). Sensitivity of CE was superior to MRE for enteric inflammation in the proximal small bowel (97% vs 71%, p=0.021), and similar to MRE and/or IC in the terminal ileum and colon (p=0.500-0.625). There were seven serious adverse advents of which three were related to the CE device. Conclusion Panenteric CE is a reliable tool for assessing Crohn's disease mucosal activity and extent compared with more invasive methods. This study demonstrates high performance of the panenteric CE as compared to MRE and/or IC without the need for multiple tests in non-stricturing Crohn's disease.
2020
colonoscopy; Crohn's disease; endoscopy; inflammatory bowel disease; small bowel disease
01 Pubblicazione su rivista::01a Articolo in rivista
Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study / Bruining, D. H.; Oliva, S.; Fleisher, M. R.; Fischer, M.; Fletcher, J. G.. - In: BMJ OPEN GASTROENTEROLOGY. - ISSN 2054-4774. - 7:1(2020). [10.1136/bmjgast-2019-000365]
File allegati a questo prodotto
File Dimensione Formato  
Bruining_Capsule-endoscopy_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 732.43 kB
Formato Adobe PDF
732.43 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1603703
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 30
social impact