We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30-900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The measurements have been performed in the LASEC laboratory at Roma Tre University, whit a custom-made electron gun. The very good stability of the beam current in the fA range, together with the picoammeter nominal resolution of 0.01 fA, allowed the measurement of the MCP absolute efficiency epsilon. We found an epsilon=(0.489 +/- 0.003) with no evident energy dependence. We fully characterised the MCP pulse shape distribution, which is quasi-Gaussian with a well visible peak above the noise level. We measured a 68 % variation of the average pulse height between 30 and 500 eV. Furthermore, with a deeper analysis of the pulse shape, and in particular of the correlation between pulse height, area and width, we found a method to discriminate single- and multi- electron events occurring within a 10 ns time window.

Absolute efficiency of a two-stage microchannel plate for electrons in the 30–900 eV energy range / Apponi, A; Pandolfi, F; Rago, I; Cavoto, G; Mariani, C; Ruocco, A. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 33:2(2022). [10.1088/1361-6501/ac3d07]

Absolute efficiency of a two-stage microchannel plate for electrons in the 30–900 eV energy range

Pandolfi, F;Rago, I;Cavoto, G;Mariani, C;
2022

Abstract

We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30-900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The measurements have been performed in the LASEC laboratory at Roma Tre University, whit a custom-made electron gun. The very good stability of the beam current in the fA range, together with the picoammeter nominal resolution of 0.01 fA, allowed the measurement of the MCP absolute efficiency epsilon. We found an epsilon=(0.489 +/- 0.003) with no evident energy dependence. We fully characterised the MCP pulse shape distribution, which is quasi-Gaussian with a well visible peak above the noise level. We measured a 68 % variation of the average pulse height between 30 and 500 eV. Furthermore, with a deeper analysis of the pulse shape, and in particular of the correlation between pulse height, area and width, we found a method to discriminate single- and multi- electron events occurring within a 10 ns time window.
2022
electron detector; absolute efficiency; low-energy electrons; microchannel plate
01 Pubblicazione su rivista::01a Articolo in rivista
Absolute efficiency of a two-stage microchannel plate for electrons in the 30–900 eV energy range / Apponi, A; Pandolfi, F; Rago, I; Cavoto, G; Mariani, C; Ruocco, A. - In: MEASUREMENT SCIENCE & TECHNOLOGY. - ISSN 0957-0233. - 33:2(2022). [10.1088/1361-6501/ac3d07]
File allegati a questo prodotto
File Dimensione Formato  
Apponi_Absolute efficiency_2022.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.73 MB
Formato Adobe PDF
4.73 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1602223
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact