The EU Framework 7 project SPIDIA was the occasion for development of NMR approaches to evaluate the impact of different pre-analytical treatments on the quality of biological samples dedicated to metabolomics. Systematic simulation of different pre-analytical procedures was performed on urine and blood serum and plasma. Here we review the key aspects of these studies that have led to the development of CEN technical specifications, to be translated into ISO/IS in the course of the EU Horizon 2020 project SPIDIA4P. Inspired by the SPIDIA results, follow-up research was performed, extending the analysis to different sample types and to the different effects of long-term storage. The latter activity was in conjunction with the local European da Vinci Biobank. These results (which partially contributed to the ANNEX of CEN/TS 16945“MOLECULAR IN VITRO DIAGNOSTIC EXAMINATIONS - SPECIFICATIONS FOR PRE-EXAMINATION PROCESSES FOR METABOLOMICS IN URINE, VENOUS BLOOD SERUM AND PLASMA”)are presented in detail.

NMR for sample quality assessment in metabolomics / Ghini, V.; Quaglio, D.; Luchinat, C.; Turano, P.. - In: NEW BIOTECHNOLOGY. - ISSN 1871-6784. - 52:(2019), pp. 25-34. [10.1016/j.nbt.2019.04.004]

NMR for sample quality assessment in metabolomics

Quaglio D.
Secondo
;
2019

Abstract

The EU Framework 7 project SPIDIA was the occasion for development of NMR approaches to evaluate the impact of different pre-analytical treatments on the quality of biological samples dedicated to metabolomics. Systematic simulation of different pre-analytical procedures was performed on urine and blood serum and plasma. Here we review the key aspects of these studies that have led to the development of CEN technical specifications, to be translated into ISO/IS in the course of the EU Horizon 2020 project SPIDIA4P. Inspired by the SPIDIA results, follow-up research was performed, extending the analysis to different sample types and to the different effects of long-term storage. The latter activity was in conjunction with the local European da Vinci Biobank. These results (which partially contributed to the ANNEX of CEN/TS 16945“MOLECULAR IN VITRO DIAGNOSTIC EXAMINATIONS - SPECIFICATIONS FOR PRE-EXAMINATION PROCESSES FOR METABOLOMICS IN URINE, VENOUS BLOOD SERUM AND PLASMA”)are presented in detail.
2019
Plasma; Pre-analytics; Serum; Urine; Humans; Quality Control; Serum; Time Factors; Magnetic Resonance Spectroscopy; Metabolomics
01 Pubblicazione su rivista::01a Articolo in rivista
NMR for sample quality assessment in metabolomics / Ghini, V.; Quaglio, D.; Luchinat, C.; Turano, P.. - In: NEW BIOTECHNOLOGY. - ISSN 1871-6784. - 52:(2019), pp. 25-34. [10.1016/j.nbt.2019.04.004]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1600383
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 41
social impact