Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.

An update on nickel-titanium rotary instruments in endodontics: mechanical characteristics, testing and future perspective—An overview / Zanza, A.; D'Angelo, M.; Reda, R.; Gambarini, G.; Testarelli, L.; Di Nardo, D.. - In: BIOENGINEERING. - ISSN 2306-5354. - 8:12(2021). [10.3390/bioengineering8120218]

An update on nickel-titanium rotary instruments in endodontics: mechanical characteristics, testing and future perspective—An overview

Zanza A.
Primo
Conceptualization
;
D'angelo M.
Secondo
Writing – Original Draft Preparation
;
Reda R.
Methodology
;
Gambarini G.
Writing – Review & Editing
;
Testarelli L.
Penultimo
Methodology
;
Di Nardo D.
Ultimo
Methodology
2021

Abstract

Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.
2021
endodontic rotary instruments; endodontics; nickel-titanium alloy; root canal treatment
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
An update on nickel-titanium rotary instruments in endodontics: mechanical characteristics, testing and future perspective—An overview / Zanza, A.; D'Angelo, M.; Reda, R.; Gambarini, G.; Testarelli, L.; Di Nardo, D.. - In: BIOENGINEERING. - ISSN 2306-5354. - 8:12(2021). [10.3390/bioengineering8120218]
File allegati a questo prodotto
File Dimensione Formato  
Zanza_Update-on-nickel-titanium_2021.pdf

accesso aperto

Note: https://www.mdpi.com/2306-5354/8/12/218
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.12 MB
Formato Adobe PDF
2.12 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1600266
Citazioni
  • ???jsp.display-item.citation.pmc??? 26
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 45
social impact