The QUIJOTE-CMB project has been described in previous publications. Here we present the current status of the QUIJOTE multi-frequency instrument (MFI) with five separate polarimeters (providing 5 independent sky pixels): two which operate at 10-14 GHz, two which operate at 16-20 GHz, and a central polarimeter at 30 GHz. The optical arrangement includes 5 conical corrugated feedhorns staring into a dual reflector crossed-draconian system, which provides optimal cross-polarization properties (designed to be < -35 dB) and symmetric beams. Each horn feeds a novel cryogenic on-axis rotating polar modulator which can rotate at a speed of up to 1 Hz. The science driver for this first instrument is the characterization of the galactic emission. The polarimeters use the polar modulator to derive linear polar parameters Q, U and I and switch out various systematics. The detection system provides optimum sensitivity through 2 correlated and 2 total power channels. The system is calibrated using bright polarized celestial sources and through a secondary calibration source and antenna. The acquisition system, telescope control and housekeeping are all linked through a real-time gigabit Ethernet network. All communication, power and helium gas are passed through a central rotary joint. The time stamp is synchronized to a GPS time signal. The acquisition software is based on PLCs written in Beckhoffs TwinCat and ethercat. The user interface is written in LABVIEW. The status of the QUIJOTE MFI will be presented including pre-commissioning results and laboratory testing. © 2012 SPIE.

The status of the Quijote multi-frequency instrument / Hoyland, R. J.; Aguiar-Gonzalez, M.; Aja, B.; Arino, J.; Artal, E.; Barreiro, R. B.; Blackhurst, E. J.; Cagigas, J.; Cano De Diego, J. L.; Casas, F. J.; Davis, R. J.; Dickinson, C.; Arriaga, B. E.; Fernandez-Cobos, R.; De La Fuente, L.; Genova-Santos, R.; Gomez, A.; Gomez, C.; Gomez-Renasco, F.; Grainge, K.; Harper, S.; Herran, D.; Herreros, J. M.; Herrera, G. A.; Hobson, M. P.; Lasenby, A. N.; Lopez-Caniego, M.; Lopez-Caraballo, C.; Maffei, B.; Martinez-Gonzalez, E.; Mcculloch, M.; Melhuish, S.; Mediavilla, A.; Murga, G.; Ortiz, D.; Piccirillo, L.; Pisano, G.; Rebolo-Lopez, R.; Rubino-Martin, J. A.; Luis Ruiz, J.; Sanchez De La Rosa, V.; Sanquirce, R.; Vega-Moreno, A.; Vielva, P.; Viera-Curbelo, T.; Villa, E.; Vizcarguenaga, A.; Watson, R. A.. - 8452:(2012). (Intervento presentato al convegno Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VI tenutosi a Amsterdam, nld) [10.1117/12.925349].

The status of the Quijote multi-frequency instrument

Pisano G.;
2012

Abstract

The QUIJOTE-CMB project has been described in previous publications. Here we present the current status of the QUIJOTE multi-frequency instrument (MFI) with five separate polarimeters (providing 5 independent sky pixels): two which operate at 10-14 GHz, two which operate at 16-20 GHz, and a central polarimeter at 30 GHz. The optical arrangement includes 5 conical corrugated feedhorns staring into a dual reflector crossed-draconian system, which provides optimal cross-polarization properties (designed to be < -35 dB) and symmetric beams. Each horn feeds a novel cryogenic on-axis rotating polar modulator which can rotate at a speed of up to 1 Hz. The science driver for this first instrument is the characterization of the galactic emission. The polarimeters use the polar modulator to derive linear polar parameters Q, U and I and switch out various systematics. The detection system provides optimum sensitivity through 2 correlated and 2 total power channels. The system is calibrated using bright polarized celestial sources and through a secondary calibration source and antenna. The acquisition system, telescope control and housekeeping are all linked through a real-time gigabit Ethernet network. All communication, power and helium gas are passed through a central rotary joint. The time stamp is synchronized to a GPS time signal. The acquisition software is based on PLCs written in Beckhoffs TwinCat and ethercat. The user interface is written in LABVIEW. The status of the QUIJOTE MFI will be presented including pre-commissioning results and laboratory testing. © 2012 SPIE.
2012
Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VI
B-modes; CMBr; Foregrounds; Instrumentation; Mapping; Polarization; Spectrometer
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
The status of the Quijote multi-frequency instrument / Hoyland, R. J.; Aguiar-Gonzalez, M.; Aja, B.; Arino, J.; Artal, E.; Barreiro, R. B.; Blackhurst, E. J.; Cagigas, J.; Cano De Diego, J. L.; Casas, F. J.; Davis, R. J.; Dickinson, C.; Arriaga, B. E.; Fernandez-Cobos, R.; De La Fuente, L.; Genova-Santos, R.; Gomez, A.; Gomez, C.; Gomez-Renasco, F.; Grainge, K.; Harper, S.; Herran, D.; Herreros, J. M.; Herrera, G. A.; Hobson, M. P.; Lasenby, A. N.; Lopez-Caniego, M.; Lopez-Caraballo, C.; Maffei, B.; Martinez-Gonzalez, E.; Mcculloch, M.; Melhuish, S.; Mediavilla, A.; Murga, G.; Ortiz, D.; Piccirillo, L.; Pisano, G.; Rebolo-Lopez, R.; Rubino-Martin, J. A.; Luis Ruiz, J.; Sanchez De La Rosa, V.; Sanquirce, R.; Vega-Moreno, A.; Vielva, P.; Viera-Curbelo, T.; Villa, E.; Vizcarguenaga, A.; Watson, R. A.. - 8452:(2012). (Intervento presentato al convegno Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VI tenutosi a Amsterdam, nld) [10.1117/12.925349].
File allegati a questo prodotto
File Dimensione Formato  
Hoyland_The status of the QUIJOTE_2012.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 3.55 MB
Formato Adobe PDF
3.55 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1585726
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact