Purpose: To present a modified surgical technique, based on a combination of human amniotic membrane (hAM) patch and autologous Platelet-rich plasma (PRP) in a case of recurrent retinal detachment (RRD) due to a perivascular retinal hole over an area of staphyloma in an eye with pathologic myopia. Methods: Presenting the surgical technique with the disposal of surgical video. After performing 23-gauge pars plana vitrectomy (PPV) the hAM patch was inserted under the neuroretina through the perivascular hole and PRP was injected on top to speed up the closure of the hole. To complete the surgical procedure High Viscosity Silicon oil (5000cst) was used as tamponade. The patient was prescribed to maintain a face-down position for the first 3 days after the operation. Follow-up was evaluated through Optical coherence tomography (OCT) scans. Results: The 3 days postoperative OCT showed a flat retina with the filling of the myopic staphyloma. The hAM patch was well positioned and the retinal hole could not be identified. At 6 weeks from intervention, the site of the retinal hole at OCT scan was covered by new tissue. Silicone oil was removed 3 months later with no recurrence. Conclusion: hAM transplantation is a novel technique in case of retinal detachment recurrences to seal retinal holes over high myopic chorioretinal atrophy. The adjunctive use of PRP and high viscosity silicon oil allows to reducing the standard face-down positioning timing, representing a valid solution for elderly patients who have difficulties maintaining the position for long periods.

Human amniotic membrane patch and platelet-rich plasma to promote retinal hole repair in a recurrent retinal detachment / Di Tizio, F.; Gattazzo, I.; Di Staso, F.; Di Pippo, M.; Guglielmelli, F.; Scuderi, G.. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 31:3(2021), pp. 1-4. [10.1177/1120672120953314]

Human amniotic membrane patch and platelet-rich plasma to promote retinal hole repair in a recurrent retinal detachment

Gattazzo I.
;
Di Staso F.;Di Pippo M.;Scuderi G.
2021

Abstract

Purpose: To present a modified surgical technique, based on a combination of human amniotic membrane (hAM) patch and autologous Platelet-rich plasma (PRP) in a case of recurrent retinal detachment (RRD) due to a perivascular retinal hole over an area of staphyloma in an eye with pathologic myopia. Methods: Presenting the surgical technique with the disposal of surgical video. After performing 23-gauge pars plana vitrectomy (PPV) the hAM patch was inserted under the neuroretina through the perivascular hole and PRP was injected on top to speed up the closure of the hole. To complete the surgical procedure High Viscosity Silicon oil (5000cst) was used as tamponade. The patient was prescribed to maintain a face-down position for the first 3 days after the operation. Follow-up was evaluated through Optical coherence tomography (OCT) scans. Results: The 3 days postoperative OCT showed a flat retina with the filling of the myopic staphyloma. The hAM patch was well positioned and the retinal hole could not be identified. At 6 weeks from intervention, the site of the retinal hole at OCT scan was covered by new tissue. Silicone oil was removed 3 months later with no recurrence. Conclusion: hAM transplantation is a novel technique in case of retinal detachment recurrences to seal retinal holes over high myopic chorioretinal atrophy. The adjunctive use of PRP and high viscosity silicon oil allows to reducing the standard face-down positioning timing, representing a valid solution for elderly patients who have difficulties maintaining the position for long periods.
2021
human amniotic membrane; optical coherence tomography; pars plana vitrectomy; pathological myopia; platelet-rich plasma; recurrent retinal detachment; retinal hole; vitreoretinal surgery; aged; amnion; humans; retrospective studies; tomography, optical coherence; visual acuity; vitrectomy; platelet-rich plasma; retinal detachment; retinal perforations
01 Pubblicazione su rivista::01a Articolo in rivista
Human amniotic membrane patch and platelet-rich plasma to promote retinal hole repair in a recurrent retinal detachment / Di Tizio, F.; Gattazzo, I.; Di Staso, F.; Di Pippo, M.; Guglielmelli, F.; Scuderi, G.. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - 31:3(2021), pp. 1-4. [10.1177/1120672120953314]
File allegati a questo prodotto
File Dimensione Formato  
DiTizio_Human-amniotic-membrane_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 314.15 kB
Formato Adobe PDF
314.15 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1575130
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact