Background: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. Methods: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. Results: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10–20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. Conclusions: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.

Home delivery of the communicator for remote monitoring of cardiac implantable devices: a multicenter experience during the covid-19 lockdown / Magnocavallo, M.; Bernardini, A.; Mariani, M. V.; Piro, A.; Marini, M.; Nicosia, A.; Adduci, C.; Rapacciuolo, A.; Saporito, D.; Grossi, S.; Santarpia, G.; Vaccaro, P.; Rordorf, R.; Pentimalli, F.; Giunta, G.; Campari, M.; Valsecchi, S.; Lavalle, C.. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 44:6(2021), pp. 995-1003. [10.1111/pace.14251]

Home delivery of the communicator for remote monitoring of cardiac implantable devices: a multicenter experience during the covid-19 lockdown

Magnocavallo M.
Primo
;
Bernardini A.
Secondo
;
Mariani M. V.;Piro A.;Adduci C.;Lavalle C.
Ultimo
2021

Abstract

Background: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. Methods: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. Results: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10–20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. Conclusions: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.
2021
cardiac implantable electronic device; covid-19; follow-up; remote monitoring; arrhythmias, Cardiac; COVID-19; female; humans; incidence; Italy; male; pacemaker, artificial; pandemics; pneumonia, viral; remote sensing technology; SARS-CoV-2; defibrillators, implantable; home care services; physical distancing
01 Pubblicazione su rivista::01a Articolo in rivista
Home delivery of the communicator for remote monitoring of cardiac implantable devices: a multicenter experience during the covid-19 lockdown / Magnocavallo, M.; Bernardini, A.; Mariani, M. V.; Piro, A.; Marini, M.; Nicosia, A.; Adduci, C.; Rapacciuolo, A.; Saporito, D.; Grossi, S.; Santarpia, G.; Vaccaro, P.; Rordorf, R.; Pentimalli, F.; Giunta, G.; Campari, M.; Valsecchi, S.; Lavalle, C.. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 44:6(2021), pp. 995-1003. [10.1111/pace.14251]
File allegati a questo prodotto
File Dimensione Formato  
Magnocavallo_Home delivery_2021.pdf

accesso aperto

Note: https://onlinelibrary.wiley.com/doi/10.1111/pace.14251
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.35 MB
Formato Adobe PDF
1.35 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1573500
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact