Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the 220Rn-216Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of 216Po half-life, estimated as (143.3±2.8) ms.
Measurement of 216Po half-life with the CUPID-0 experiment / Azzolini, O.; Beeman, J. W.; Bellini, F.; Beretta, M.; Biassoni, M.; Brofferio, C.; Bucci, C.; Capelli, S.; Cardani, L.; Carniti, P.; Caracciolo, V.; Casali, N.; Chiesa, D.; Clemenza, M.; Colantoni, I.; Cremonesi, O.; Cruciani, A.; Dafinei, I.; D'Addabbo, A.; Di Domizio, S.; Ferroni, F.; Gironi, L.; Giuliani, A.; Gorla, P.; Gotti, C.; Keppel, G.; Martinez, M.; Nagorny, S.; Nastasi, M.; Nisi, S.; Nones, C.; Orlandi, D.; Pagnanini, L.; Pallavicini, M.; Pattavina, L.; Pavan, M.; Pessina, G.; Pettinacci, V.; Pirro, S.; Pozzi, S.; Previtali, E.; Puiu, A.; Rusconi, C.; Schaffner, K.; Tomei, C.; Vignati, M.; Zolotarova, A.. - In: PHYSICS LETTERS. SECTION B. - ISSN 0370-2693. - 822:(2021), p. 136642. [10.1016/j.physletb.2021.136642]
Measurement of 216Po half-life with the CUPID-0 experiment
Bellini F.;Casali N.;Dafinei I.;Vignati M.;
2021
Abstract
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the 220Rn-216Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of 216Po half-life, estimated as (143.3±2.8) ms.File | Dimensione | Formato | |
---|---|---|---|
Azzolini_Measurement of 216Po half-life_2021.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
346.32 kB
Formato
Adobe PDF
|
346.32 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.