In this paper, we provide an in-depth electrochemical characterization of a label-free impedimetric immunosensor for rapid detection of ochratoxin A. The sensor was based on a carbodiimide-mediated amide coupling reaction to immobilize a specific ochratoxin A antibody onto 4-mercaptobenzoic acid-modified commercial screen-printed gold electrode. Different variables affecting the performance of the developed sensor were optimized. Cyclic voltammetry and electrochemical impedance spectroscopy were used to analyse modifications of the interfacial properties occurring at each step of the biosensor assembly. The free electrode surface area, the diffusion coefficient, the peak-to-peak separation, the heterogeneous electron transfer constant, and charge transfer resistance have been calculated and compared. The decrease of charge transfer resistance values was linearly proportional to the ochratoxin A concentration in the range of 0.37– 2.86 ng/mL, with a detection limit of 0.19 ng/mL, a limit of quantification of 0.40 ng/mL, very good selectivity, reproducibility, and storage stability in the absence of antifouling agents. Surface morphology and topographic data at each step of the immunosensor assembly were studied by Atomic Force Microscopy, which also provided information on the specific binding of ochratoxin A. Finally, contact angle measurements revealed the hydrophilicity evolution of the surface during sensor assembly enabling OTA binding.

Electrochemical and morphological layer-by-layer characterization of electrode interfaces during a label-free impedimetric immunosensor build-up: The case of ochratoxin A / Cancelliere, Rocco; Albano, David; Brugnoli, Benedetta; Buonasera, Katia; Leo, Gabriella; Margonelli, Andrea; Rea, Giuseppina. - In: APPLIED SURFACE SCIENCE. - ISSN 0169-4332. - 567:(2021), pp. 1-12. [10.1016/j.apsusc.2021.150791]

Electrochemical and morphological layer-by-layer characterization of electrode interfaces during a label-free impedimetric immunosensor build-up: The case of ochratoxin A

Albano, David;Brugnoli, Benedetta;
2021

Abstract

In this paper, we provide an in-depth electrochemical characterization of a label-free impedimetric immunosensor for rapid detection of ochratoxin A. The sensor was based on a carbodiimide-mediated amide coupling reaction to immobilize a specific ochratoxin A antibody onto 4-mercaptobenzoic acid-modified commercial screen-printed gold electrode. Different variables affecting the performance of the developed sensor were optimized. Cyclic voltammetry and electrochemical impedance spectroscopy were used to analyse modifications of the interfacial properties occurring at each step of the biosensor assembly. The free electrode surface area, the diffusion coefficient, the peak-to-peak separation, the heterogeneous electron transfer constant, and charge transfer resistance have been calculated and compared. The decrease of charge transfer resistance values was linearly proportional to the ochratoxin A concentration in the range of 0.37– 2.86 ng/mL, with a detection limit of 0.19 ng/mL, a limit of quantification of 0.40 ng/mL, very good selectivity, reproducibility, and storage stability in the absence of antifouling agents. Surface morphology and topographic data at each step of the immunosensor assembly were studied by Atomic Force Microscopy, which also provided information on the specific binding of ochratoxin A. Finally, contact angle measurements revealed the hydrophilicity evolution of the surface during sensor assembly enabling OTA binding.
2021
electron transfer kinetics; diffusivity process; label-free immunosensors; ochratoxin A immunosensor; contact angle
01 Pubblicazione su rivista::01a Articolo in rivista
Electrochemical and morphological layer-by-layer characterization of electrode interfaces during a label-free impedimetric immunosensor build-up: The case of ochratoxin A / Cancelliere, Rocco; Albano, David; Brugnoli, Benedetta; Buonasera, Katia; Leo, Gabriella; Margonelli, Andrea; Rea, Giuseppina. - In: APPLIED SURFACE SCIENCE. - ISSN 0169-4332. - 567:(2021), pp. 1-12. [10.1016/j.apsusc.2021.150791]
File allegati a questo prodotto
File Dimensione Formato  
Cancelliere_Electrochemical_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 6.83 MB
Formato Adobe PDF
6.83 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1566717
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 20
social impact